8
DB CONNECTION SERVICE AND SETTING TOOL

8.8.1 Access log

The communication contents of the MES interface module and DB Connection Service are
output to the access log.
The following explains the access log contents.
(1) Service start/end
Item
Output log format
[Date] [Error code] Service Start
Example
2007/10/01 12:00:00.000 0×00000000 Service Start
Item
Output log format
[Date] [Error code] Service Stop
Example
2007/10/01 12:00:00.000 0x00000000 Service Stop
(2) Connection/disconnection from the MES interface module or the MES
Table 8.13 Connection from the MES interface module or the MES Interface Function Configuration Tool
Item
Output log format
[Date] [Error code] SID [Session ID]:MIFWS Connected:[Source IP]:[Target data source]:[Connection User Name]
Example
2007/10/01 12:00:00.000 0x00000000 SID 00000001:MIFWS Connected:192.168.3.3:DataSource:User Name
Table 8.14 Disconnection from the MES interface module or the MES Interface Function Configuration Tool
Item
Output log format
[Date] [Error code] SID [Session ID]:MIFWS Disconnected:[Source IP]:[Target data source]:[Connection User Name]
Example
2007/10/01 12:00:00.000 0x00000000 SID 00000001:MIFWS Disconnected:192.168.3.3:DataSource:User Name
8
- 24
8.8 Output Log Specifications
8.8.1 Access log
(a) Start
Table 8.11 Service start
(b) End
Table 8.12 Service end
Interface Function Configuration Tool
(a) Connection
(b) Disconnection
Description
Description
Description
Description