7
MES INTERFACE FUNCTION CONFIGURATION TOOL
(4) Startup logging
(a) Set whether to output the startup history of the job to the log or not.
(b) When the log capacity becomes full (Log capacity: 2MB × 2)
(c) When this function is enabled, a processing time is required for saving or deleting
(5) Test mode
(a) Set whether to operate the job in test mode or not.
(b) When [Test mode] is selected
If this function is enabled, the job startup timing can be checked during system
start-up or tune-up.
When the [Startup logging] box is checked, the startup history of the job (date and
time, job name) is saved on a CompactFlash card.
The startup log can be checked from [Online] - [View working log].
Section 7.12.5 Checking the working log of the MES interface module
The first half of the data are deleted.
The latest log is stored after the remaining data.
the startup history of the job.
It is recommended to disable this function during system operation.
Up to 4 jobs can be set to [Test mode].
When the [Test mode] box is checked, the test mode is activated, and execution
details of the job can be confirmed before operation.
Execution details of the job can be checked by selecting [Online] - [View working
log] - [View details].
Section 7.12.5 Checking the working log of the MES interface module
The following are performed in the test mode.
Operations other than the following are identical to the actual operations.
• Startup data are logged.
• Detailed data are logged.
• No data are written to the programmable controller CPU.
• No data are written to the database.
7.10 Job Setting
7.10.1 Setting items in Job setting
1
2
3
4
5
6
7
8
7
- 61