Jackson TempStar Series Installation, Operation And Service Manual page 32

Door-type dishmachines
Table of Contents

Advertisement

PARTS
EXHAUST FAN
CONTROL
MAXIMUM LOAD
1 AMP , 240/120 V AC
INPUT L1
OUTPUT TO
(EXTERNAL)
EXT. RELAY
Fuse,1 A, Fast-acting
05999-004-47-87
Littelfuse P/N - 0312001.HXP
Qty - 2 (2 per output)
26
1
07610-003-61-42-V
208/230 V
WARNING: DISCONNECT POWER TO MACHINE BEFORE SERVICING
DETERGENT
CONSTANT VOLTAGE
RINSE-AID DISPENSER
DISPENSER
CONNECTION
CONNECTION
CONNECTION
LIVE WHEN MACHINE
LIVE WHEN RINSE
LIVE WHEN WASH
POWER SWITCH IS ON
VALVE IS OPEN
PUMP MOTOR IS ON
FUSE: 3 AMP SLOW-ACTING
FUSE: 3 AMP SLOW-ACTING
FUSE: 3 AMP SLOW-ACTING
L1 OUT
L2 OUT
L1 OUT
L2 OUT
L1 OUT
Fuse, 3 A, Slow-acting
05999-004-44-34
Littelfuse P/N - 0313003.HXP
Qty - 6 (2 per output)
36
34
33
Fuses
or
EXHAUST FAN
MAXIMUM LOAD
1 AMP , 240/120 V AC
INPUT L1
L2 OUT
(EXTERNAL)
Fuse,1 A, Fast-acting
05999-004-47-87
Littelfuse P/N - 0312001.HXP
Qty - 2 (2 per output)
CONTROL BOX
460 V
WARNING: DISCONNECT POWER TO MACHINE BEFORE SERVICING
CONSTANT VOLTAGE
RINSE-AID DISPENSER
CONTROL
CONNECTION
CONNECTION
LIVE WHEN MACHINE
LIVE WHEN RINSE
POWER SWITCH IS ON
VALVE IS OPEN
FUSE: 200 mA SLOW-ACTING
FUSE: 200 mA SLOW-ACTING
OUTPUT TO
EXT. RELAY
240 VAC OUT
240 VAC OUT
Fuse, 200 mA, Slow-acting
05999-004-44-33
Littelfuse P/N - 0313.200HXP
Qty - 6 (2 per output)
30
28
29
DETERGENT
DISPENSER
CONNECTION
LIVE WHEN WASH
PUMP MOTOR IS ON
FUSE: 200 mA SLOW-ACTING
240 VAC OUT
24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tempstar ltTempstar sTempstar nbTempstar ver

Table of Contents