D9412G/D7412G | Operation & Installation Guide |
12.0 Programmer/Accessory
Connections
12.1

Programmer Connector

Refer to the D5200 Operation Manual for complete
information on using the D5200 programmer.
To connect and disconnect the programmer:
1. Lock the Reset Pin (see Figure 30).
2. Connect the D5200 Data/Power cord into the
programmer connector.
3. Perform the desired programming function (send or
receive program).
4. Disconnect the programmer.

Figure 30: Reset Pin

Reset Pin
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
32
RED
POWER +
YELLOW
DATA BUS A
31
GREEN
DATA BUS B
30
29
BLACK
COMMON
1 - Reset Pin locked (closed)
2 - Rest Pin normal (open) for normal panel operation
12. 1 . 1

Programmer Access Reports

When a program is sent to the panel, the panel sends a
Prog Access OK Report 10 seconds after the handler
exits or when the programmer disconnects. The prompt
in routing must be programmed YES to send this
report.
Bosch Security Systems | 10/03 | 43488E

12.0 Programmer/Accessory Connections

12.2
Use the accessory connector to connect the panel to the
D928 Dual Phone Line Switcher. The accessory
connector is on the bottom right corner of the I/O
board (see Figure 31). The D928 lets the panel use two
telephone lines to transmit reports.
See Section 6.12 D928 Dual Phone Line Switcher for
installation and operating instructions.

Figure 31: Programmer and Accessory Connections

1
2

1 - Accessory connector

2 - Programming connector
Accessory Connector
NEX IN 2
NEX POWER +
ZONEX COMMON
Point 8
GND FAULT
Detect
D
I
S
A
B
L
L
GRN
E
E
EN | 61
26
25
24
23
PROG
CONN
1
2