D9412G/D7412G | Operation & Installation Guide | Appendix A
A.6

D7412G Control Panel, 3 of 3

Figure 39: D7412G System Wiring Diagram, 3 of 3

46729G
LEDs Off When Normal
Charging Status
YEL
RED
Low Battery - 12.1 VDC
Reference D9412G/D7412G Approved Applications Compliance Guide (P/N:43494___)
10.2 VDC - Battery Load Shed
Reference D9000/D9000G Series Technogram (P/N:33284___)
CLASS 2 TRANSFORMER
The Power Supply Provides a Maximum of 1.4 Amps For The Control
16.5 VAC 40 VA 60 Hz
Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation
Model D1640
and Installation Guide (P/N:43488___).
Internally Fused - Do Not short
All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power
Requires Unswitched Outlet
Do Not Share With Other Equipment
Limited. Requirements For Battery Standby Time May Reduce Allowable Output.
CAUTION:
+ AUX POWER
WARNING!
BATTERY NEGATIVE ONLY
Multi-Battery Installation Requires
Maximum Charging
Model D122 Dual Battery Harness.
Current 1.4 Amps.
Improper Installation Can Be a Fire
BATTERY POSITIVE ONLY
Hazard.
PROGRAMMABLE
This equipment should be installed in accordance with the NFPA 70 (National Electrical Code)
RELAY A
ALARM OUTPUTS
and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire
Terminals
Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper
7
&
8
RELAY B
installation, operation, testing, maintenance, evacuation planning and repair service is to be provided
Requires Optional
with this equipment.
Model D136 Relay
In ALT ALARM
D7412G Control/Communicator is UL Listed For Central Station, Local, Remote Station and Household
RELAY C
& SW AUX
Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm.
System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years.
COMMON
The types of initiating circuits the panel has been approved for are A, M, W, SS.
EARTH GROUND
GROUND FAULT DETECT
Point 1 Point 2
Enabled
Disabled
GROUND START
LOOP START
GND START
GROUND START
PHONE
Requires Relay
RED
LED
Model D136 in
11
12
ON WH EN
Ground
COMMU NIC ATIN G
Start Socket
OFF W H EN IDLE
D8125
4
-
+
5
Note: All external connections except Terminal 5
(battery positive) are inherently power limited.
Bosch Security Systems | 10/03 | 43488E
Digital Alarm Communicator Transmitter
Reset Pin
For System Wiring Diagram, Issue A
Disable All Except Battery
Charging And Programming
For Compatible Smoke Detectors
POWER SUPPLY REQUIREMENTS
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
See D9412G/D7412G Operation and Installation Guide (P/N:43488)
GREEN
DATA BUS B
For Power Requirements Relating to Terminals 6
7
Battery: Replace Every 3 to
BLACK
COMMON
5 years with Model D126, 12 V
7 Amp Hr Lead Acid Battery
N.F.P.A.
ZONEX OUT 1
Style 3.5
Signaling
Line
Circuits
ZONEX IN 1
VOLTAGE RANGES
Open
3.7 - 5.0 VDC
Normal 2.0 - 3.0 VDC
Short
0.0 - 1.3 VDC
Point 3 Point 4
Point 5 Point 6
Point 7 Point 8
Point 8
PROG
GND FAULT
CONN
Detect
D
E
I
N
S
A
A
B
B
L
13
14
15
16
17
18
19
20
21
22
L
GRN
E
E
D1255
1
3
3
3
3
3
3
D8128D
6
D8129
7
1 - Up to 8 supervised
2 - Up to 3 supervised
3 - Power limited, supervised
4 - POPEX #1
5 - Up to 119 D9127U/T POPITs or up to 63 D8127U/T
POPITs.
6 - Zx 1: 15 D8128Ds
7 - Zx 1: Up to 8 maximum
D1256
D1257
D1260
D9210B
D9131A
1
D9133TTL-E
EN | 70