3. While cleaning the hopper use the brush provided with the unit to clean the cold plate surface. To
accomplish this, the brush needs to be extended through the opening in the bottom of the hopper.

Yearly Maintenance:

1. Have the water pump and check valve inspected and cleaned by a qualified service technician.
2. Has the CO2 gas check valve inspected and cleaned by a qualified service technician.
3. Remove the unit's splash and cold plate cover to clean and sanitize the cold plate surface. (See the
Cleaning the Cold Plate section shown later in this manual).

Lid Dispenser Cleaning

The lid dispensers are manufactured out of materials that can survive chlorine-based cleaners and warm water
<100°F. Ensure that the parts are thoroughly dried before refilling with lids.
Lid dispenser parts should not be soaked in the power soak washing machine as this will result in the
parts getting scratched. Instead the dispenser parts should be rinsed in warm soapy water when dry.

Ice Chute Cleaning

The Ice chute needs to be cleaned daily to remove buildups.
NOTE: The ice chute has an built-in safety feature which disables the unit when the ice chute cover is
removed. If the ice chute cover is not properly installed the agitator and ice chute gate will not
function.

Removing and Reinstalling the Ice Chute:

1. Grab ice chute and slide up until it comes to a
stop.
2. Pull forward.
3. Properly clean the ice chute. The ice chute is
manufactured out of materials that can survive
chlorine-based cleaners and warm water
<100°F.
IMPORTANT: Do not put the ice chute into a
dishwasher.
4. Replace when finished.
5. If agitator or ice chute does not operate
remove and re-install chute cover.

Cleaning Interior Surfaces (Monthly Cleaning)

!
CAUTION:
When pouring liquid into the hopper, do not exceed the rate of 1/2 gallon per minute. Pouring more liquid into the
hopper could result in an overflow situation which may result in injury or damage to the equipment.
1. Remove agitator assembly.
2. Using a nylon bristle brush or sponge, clean the interior of the hopper, top cover and agitator assembly with
soap solution. Thoroughly rinse the hopper, cover and agitator surfaces with clean potable water.
3. Re-assemble agitator assembly. Take special care to ensure that the thumbscrew is tight.
4. Using a mechanical spray bottle filled with sanitizing solution, spray the entire interior and agitator assem-
bly. Allow to air dry.