CONTRAST ADJUSTMENT (SDTV)
Measuring Instruments
Card (Slot)
Test Points
Adjustment Points
Notes:
Perform the following adjustments after completing
the 1080/60i signal Contrast adjustment.
Set the CONTRAST data in the Setup Menu to "00".
The SR value (see the description of the HDTV
Contrast Adjustment) becomes the reference value
for the following adjustments. When this data is
changed, it is required to re-adjust the data of all of
the adjustment signals (HDTV, SDTV and NTSC/PAL).
When re-adjusting the 1080/60i signal, use the SI.
(1) Apply the 480/60i crosshatch signal to INPUT A (Terminal
Y on the Component/RGB Input Card).
(2) Set the CONTRAST potentiometer on the front panel to
the center click position.
(3) Connect the oscilloscope across TP-47G and TP-GND.
(4) Adjust SE01 in the Service Menu to set the voltage
amplitude <A> in the figure on the right to the voltage
shown in the Table2.
(5) Vary the adjustment signal and adjustment data, and re-
perform adjustments in steps 1 to 4 above (see Table 2).
Signal generator (Crosshatch signal)
Oscilloscope
Component/RGB Input Card (Slot 1)
TP-47G [CRT SOCKET PWB]
TP-GND [CRT SOCKET PWB]
S*01 (Contrast) [Service Menu]
(V. sync)
1 Vertical interval
<A>
Adjustment Signal Adjustment Data Adjustment Voltage <A>
480/60i
SE01
576/50i
SF01
480/60p
SG01
576/50p
SH01
Table 2
36 V ± 2 V
36 V ± 2 V
35 V ± 2 V
35 V ± 2 V
(No. 52152) 1-49