! INITIAL SETTING VALUE TABLE [MAIN MENU]
Setting Item
APERTURE CONTROL
LEVEL
CONTROL FREQ.
SLOT CONDITION
INPUT A – F
sub menu POSITION
AREA MARKER
MARKER SELECT
ZOOM
ASPECT SELECT
SAFEY AREA
R-MARKER SELECT
R-ZOOM
R-ASPECT SELECT
R-SAFETY AREA
COLOR MATRIX
! INITIAL SETTING VALUE TABLE [FRONT PANEL CONTROL]
Setting Item
POWER
INPUT SELECT
COLOR OFF
AREA MARKER
PULSE CROSS
ASPECT
UNDER SCAN
SCREENS CHECK
DEGAUSS
VOLUME
CONTRAST
BRIGHT
CHROMA
PHASE
Data / Variable range
00 – 10
HIGH / LOW / OFF
Type of boards installed in the rear panel slots.
SLOT1
: INPUT A, B
SLOT2
: INPUT C, D
SLOT3
: INPUT E, F
LOWER / UPPER
OFF / LINE /S. HALF / HALF+L / S. BLK / BLK. +L
OFF / ON
4 : 3 / 13 : 9 / 14 : 9
OFF / 80% / 88% / 90%
OFF / LINE / S. HALF / HALF+L / S. BLK / BLK. +L
OFF / ON
4 : 3 / 13 : 9 / 14 : 9
OFF / 80% / 88% / 90%
SELECT : MANUAL / ITU601 or ITU709
[Example when MANUAL is set]
R-Y PHASE : 90/92/94/112
R/B GAIN
: 0.56/0.68/0.79/0.86
G-Y PHASE : 236/240/244/253
G/B GAIN
: 0.30/0.34/0.40/0.45
Data / Variable range
ON / OFF
INPUT A – F
ON / OFF
00 – 50
POTENTIOMETER
Initial setting value
00
HIGH
LOWER
OFF
OFF
4 : 3
OFF
OFF
OFF
4 : 3
0FF
NORMAL
90
0.86
244
0.30
Initial setting value
OFF
INPUT A
OFF
10
Center click position
(No. 52152) 1-11