11.5 READING MEASURED VALUES

The following current values can be read in the information menu
• St = State
• Su = Sub-status
• t1 = Supply temperature ºF/ºC
• t2 = Return temperature ºF/ºC
• t3 = DHW tank temperature ºF/ºC
• t4 = Outdoor temperature ºF/ºC (Only with an optional outdoor temperature sensor)
• t5 = Solar boiler temperature ºF/ºC
• t6 = Flue gas tempreature ºF/ºC
• Sp = Internal set point ºF/ºC
• Fl = Ionization current (μA)
• ñf = Fan speed in rpm
• Pr = Water pressure psi/bar
• Po = Supplied relative heat output (%).
4x
2x
:
The current values can be read as follows:
1.
Press the two
buttons simultaneously. The symbol
2.
Confirm using
button .
current status 3 (for example).
3. Press the [+] button.
sub-status
(for example).
4. Press the [+] button.
flow temperature
5. Press the [+] button successively to scroll down to the various
parameters.
,
6. Press the [+] button.
set point
(for example).
7. Press the [+] button.
ionization current
8. Press the [+] button.
fan rotation speed
9. Press the [+] button.
water pressure
10. Press the [+] button.
modulation percentage
11. Press the [+] button. The readout cycle starts again with
12. Press the
button 2 times to return to the current operating mode.
43
is displayed, alternating with the
is displayed, alternating with the current
is displayed, alternating with the current
(for example).
,
,
,
is displayed, alternating with the internal
is displayed, alternating with the current
(for example).
is displayed, alternating with the current
(for example).
is displayed, alternating with the current
(for example).
is displayed, alternating with the current
(for example).
7703477.01 (1-03/18)