12.2 ERROR HISTORY
The boiler control is equipped with an error memory which, records the last 16 errors. In addition to storing the error codes, the
following data is also saved:
• Number of times that the error occured: (n:xx).
• Boiler operating mode selected (St:xx).
• The supply temperature (t1:xx) and the return temperature (t2:xx) when the error occured.
To view the error history, you first have to enter access code 0012.
12.2.1
ERROR HISTORY READOUT
• Press the two
buttons simultaneously and then the (+) button until the
symbol
flashes on the menu bar.
• Select the installers menu using the
display.
• Use the (-) or (+) button to input the installer code 0012.
• Press the
button. "Er:xx" appears on the display.
• The fault list can be displayed by pressing the (-) or (+) button.
• Confirm using
button. "Er:xx" is displayed with "xx" flashing = Last
error which occured, for example "2".
• Use the (-) or (+) buttons to scroll through the faults.
• Press the
button to display the details of the faults or shutdowns.
• Press the (-) or (+) buttons to view the following information:
n:1 = Number of times that the error occured.
hr = The number of operating hours.
St = State.
Su = Sub-status.
t1 = Supply temperature ºF/ºC.
t2 = Return temperature ºF/ºC.
t3 = DHW tank temperature ºF/ºC.
t4 = Outdoor temperature ºF/ºC (Only with an outdoor temperature sensor).
t5 = Solar panel temperature ºF/ºC.
t6 = Flue gas temperature ºF/ºC.
Sp = Internal set point ºF/ºC. fl = Ionization current (μA).
nf = Fan speed in rpm.
Pr = Water pressure psi/bar.
Po= Supplied relative heat output (%).
• Press the
button to interrupt the display cycle. "Er:xx" is displayed with
"xx" flashing = Last error which occured.
• Use the (-) or (+) button to scroll through the faults.
• Press the
button to show the fault list.
• Press the
button 2 times to exit the error history.