9 Settings
Fig.64
Heating curve graph
CP000
CP000
Reading out measured values
9.4
Fig.65
INFO menu access
Tab.28
Read-only parameter list (not editable)
Setting
Description
(read only)
AM001
DHW (Domestic Hot Water) mode enabled (0: Disabled, 1: Enabled)
AM010
Pump speed (0 ÷ 100%)
AM011
Service required (0: Disabled, 1: Enabled)
AM012
Status of appliance
AM014
Sub Status of appliance
AM015
Pump operation (0: Disabled, 1: Enabled)
58
Combi 2
Tout (°C)
Tout (°C)
Proceed as described below to access the info menu:
Press the
The
Press the
Turn the
Press the
Note
Explain to the user how to select a different temperature curve and
how the outdoor sensor regulates the boiler flow temperature.
Important
When an OpenTherm controller is connected adjustment of the
boiler, e.g. heating temperature, is made using the OpenTherm
controller rather than the boiler controls. The boiler controls are
overridden by the OpenTherm control. Please check the function-
ality with the manufacturer of the OpenTherm controller.
CP000
CP230 = 1.5
CP210 = 15
PreheatSetpoint = 0
Tout: temperature detected by the outside sensor (°C)
SP_CH: Heating flow temperature setpoint (°C)
CP200 = 20
CP210 = 15
PreheatSetpoint = 0
key;
symbol flashes on the display;
key to access the INFO menu;
knob to view the settings;
key to exit.
Tout (°C)
CP200 = 20
CP230 = 1.5
PreheatSetpoint = 0
BO-0000232
Value
0/1
%
0/1
List of statuses
List of sub-statuses
0/1