Measured Values; A.10 Measured Values - Siemens Siprotec 7VK61 Manual

Breaker management device
Hide thumbs Also See for Siprotec 7VK61:
Table of Contents

Advertisement

A.10

Measured Values

No.
Description
601
I L1 (IL1 =)
602
I L2 (IL2 =)
603
I L3 (IL3 =)
610
3I0 (zero sequence) (3I0 =)
619
I1 (positive sequence) (I1
620
I2 (negative sequence) (I2
621
U L1-E (UL1E=)
622
U L2-E (UL2E=)
623
U L3-E (UL3E=)
624
U L12 (UL12=)
625
U L23 (UL23=)
626
U L31 (UL31=)
627
Uen (Uen =)
631
3U0 (zero sequence) (3U0 =)
632
Measured value Usy2 (Usy2=)
633
Ux (separate VT) (Ux
634
U1 (positive sequence) (U1
635
U2 (negative sequence) (U2
636
Measured value U-diff (Usy1- Usy2) (Udiff =) Measurement
637
Measured value Usy1 (Usy1=)
638
Measured value Usy2 (Usy2=)
641
P (active power) (P =)
642
Q (reactive power) (Q =)
643
Power Factor (PF =)
644
Frequency (Freq=)
645
S (apparent power) (S =)
646
Frequency fsy2 (F-sy2 =)
647
Frequency difference (F-diff=)
648
Angle difference (ϕ-diff=)
649
Frequency fsy1 (F-sy1 =)
684
U0 (zero sequence) (U0 =)
888
Pulsed Energy Wp (active) (Wp(puls))
889
Pulsed Energy Wq (reactive) (Wq(puls))
924
Wp Forward (Wp+=)
925
Wq Forward (Wq+=)
SIPROTEC, 7VK61, Manual
C53000-G1176-C159-3, Release date 05.2009
Function
Measurement
Measurement
Measurement
Measurement
=)
Measurement
=)
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
=)
Measurement
=)
Measurement
=)
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Measurement
Energy
Energy
Energy
Energy
IEC 60870-5-103
94
148
No
9
134
124
No
9
94
148
No
9
134
124
No
9
94
148
No
9
134
124
No
9
134
124
No
9
-
-
-
-
-
-
-
-
94
148
No
9
134
124
No
9
94
148
No
9
134
124
No
9
94
148
No
9
134
124
No
9
134
124
No
9
134
124
No
9
134
124
No
9
134
118
No
9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
130
1
No
9
130
1
No
9
130
1
No
9
94
148
No
9
134
124
No
9
94
148
No
9
134
124
No
9
134
124
No
9
94
148
No
9
134
124
No
9
-
-
-
-
130
1
No
9
130
1
No
9
130
1
No
9
130
1
No
9
134
118
No
9
133
55
No
205
133
56
No
205
133
51
No
205
133
52
No
205
Appendix

A.10 Measured Values

Configurable in Matrix
1
CFC
CD
DD
1
2
CFC
CD
DD
2
3
CFC
CD
DD
3
14
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
4
CFC
CD
DD
4
5
CFC
CD
DD
5
6
CFC
CD
DD
6
10
CFC
CD
DD
11
CFC
CD
DD
12
CFC
CD
DD
1
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
2
CFC
CD
DD
3
CFC
CD
DD
1
CFC
CD
DD
7
CFC
CD
DD
7
8
CFC
CD
DD
8
13
CFC
CD
DD
9
CFC
CD
DD
9
-
CFC
CD
DD
4
CFC
CD
DD
5
CFC
CD
DD
6
CFC
CD
DD
7
CFC
CD
DD
2
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
-
CFC
CD
DD
313

Advertisement