Addr.
Parameter
610
FltDisp.LED/LCD
625A
T MIN LED HOLD
640
Start image DD
1103
FullScaleVolt.
1104
FullScaleCurr.
1107
P,Q sign
1130A
PoleOpenCurrent
1131A
PoleOpenVoltage
1133A
T DELAY SOTF
1135
Reset Trip CMD
1136
OpenPoleDetect.
1150A
SI Time Man.Cl
1151
MAN. CLOSE
1152
Man.Clos. Imp.
2601
Operating Mode
2610
Iph>>
2611
T Iph>>
2612
3I0>> PICKUP
2613
T 3I0>>
2614
I>> Telep/BI
2615
I>> SOTF
2620
Iph>
2621
T Iph>
2622
3I0>
2623
T 3I0>
2624
I> Telep/BI
2625
I> SOTF
2630
Iph> STUB
2631
T Iph STUB
2632
3I0> STUB
2633
T 3I0 STUB
SIPROTEC, 7VK61, Manual
C53000-G1176-C159-3, Release date 05.2009
Function
C
Device
Target on PU
Target on TRIP
0 .. 60 min; ∞
Device
Device
image 1
image 2
image 3
image 4
image 5
image 6
P.System Data 2
1.0 .. 1200.0 kV
P.System Data 2
10 .. 5000 A
P.System Data 2
not reversed
reversed
P.System Data 2
1A
0.05 .. 1.00 A
5A
0.25 .. 5.00 A
P.System Data 2
2 .. 70 V
P.System Data 2
0.05 .. 30.00 sec
P.System Data 2
CurrentOpenPole
Current AND CB
Pickup Reset
P.System Data 2
OFF
Current AND CB
w/ measurement
P.System Data 2
0.01 .. 30.00 sec
P.System Data 2
with Sync-check
w/o Sync-check
NO
P.System Data 2
(Setting options depend
on configuration)
Back-Up O/C
ON
OFF
0.10 .. 25.00 A; ∞
Back-Up O/C
1A
0.50 .. 125.00 A; ∞
5A
0.00 .. 30.00 sec; ∞
Back-Up O/C
0.05 .. 25.00 A; ∞
Back-Up O/C
1A
0.25 .. 125.00 A; ∞
5A
0.00 .. 30.00 sec; ∞
Back-Up O/C
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
0.10 .. 25.00 A; ∞
Back-Up O/C
1A
0.50 .. 125.00 A; ∞
5A
0.00 .. 30.00 sec; ∞
Back-Up O/C
0.05 .. 25.00 A; ∞
Back-Up O/C
1A
0.25 .. 125.00 A; ∞
5A
0.00 .. 30.00 sec; ∞
Back-Up O/C
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
0.10 .. 25.00 A; ∞
Back-Up O/C
1A
0.50 .. 125.00 A; ∞
5A
0.00 .. 30.00 sec; ∞
Back-Up O/C
0.05 .. 25.00 A; ∞
Back-Up O/C
1A
0.25 .. 125.00 A; ∞
5A
0.00 .. 30.00 sec; ∞
Back-Up O/C
Setting Options
Default Setting
Target on PU
0 min
image 1
400.0 kV
1000 A
not reversed
0.10 A
0.50 A
30 V
0.25 sec
CurrentOpenPole
w/ measurement
0.30 sec
NO
None
ON
2.00 A
10.00 A
0.30 sec
0.50 A
2.50 A
2.00 sec
YES
NO
1.50 A
7.50 A
0.50 sec
0.20 A
1.00 A
2.00 sec
NO
NO
1.50 A
7.50 A
0.30 sec
0.20 A
1.00 A
2.00 sec
Appendix
A.7 Settings
Comments
Fault Display on LED / LCD
Minimum hold time of lachted
LEDs
Start image Default Display
Measurement: Full Scale Voltage
(100%)
Measurement: Full Scale Current
(100%)
P,Q operational measured values
sign
Pole Open Current Threshold
Pole Open Voltage Threshold
minimal time for line open before
SOTF
RESET of Trip Command
open pole detector
Seal-in Time after MANUAL clo-
sures
Manual CLOSE COMMAND
generation
MANUAL Closure Impulse after
CONTROL
Operating mode
Iph>> Pickup
T Iph>> Time delay
3I0>> Pickup
T 3I0>> Time delay
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Iph> Pickup
T Iph> Time delay
3I0> Pickup
T 3I0> Time delay
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Iph> STUB Pickup
T Iph STUB Time delay
3I0> STUB Pickup
T 3I0 STUB Time delay
287