Ac Operation - Replace The Fuses; Figure 3-8. Replace The Ac Fuses - Comtech EF Data CDD-880 Installation And Operation Manual

Advanced vsat series multi receiver router
Hide thumbs Also See for CDD-880:
Table of Contents

Advertisement

CDD-880 Multi Receiver Router
Rear Panel Connections
3.4.2.2
AC Operation – Replace the Fuses
For AC operation, the unit uses two common 5mm x 20mm Slow-blow fuses – one each for line
and neutral connections. The fuses are contained on the rear panel in a fuse holder that is press-
fit into the body of the IEC power module (Figure 3-8).
WARNING – DEATH OR PERSONAL INJURY IS POSSIBLE! DISCONNECT THE POWER
SUPPLY BEFORE PROCEEDING!
CAUTION – ALWAYS REPLACE THE FUSES WITH THE CORRECT TYPE AND RATING. SEE
FIGURE 3-6 FOR THE AC FUSE SPECIFICATIONS.
Do these steps to replace the AC fuses (Figure 3-8):
Step
Task
1
Disconnect the power supply.
2
Unseat the fuse holder from the IEC power module:
Use the slot to pry the holder outward from the IEC power module.
Pull the holder straight out, and then swing the holder away from the module.
3
Remove and replace the fuses as necessary.
4
Re-seat the fuse holder in the IEC power module.

Figure 3-8. Replace the AC Fuses

3–13
MN-CDD880
Revision 2