Appendix G
d) Use the drop-down list in the Tx Dynamic Power Control (DPC) Configuration section of
the Configuration | WAN | Mod | DPC page to enable DPC. Click [Submit], and allow
power to target (ACM operation is not required).
e) In the Power Reference section of the Configuration | WAN | Mod | DPC page, click
[Set Reference].
f) If [Set Reference] fails, note the failure, correct the condition, and click [Set Reference]
once more.
G.4.1.4

DPC Status Reporting

Once reference calibration is complete, the Tx Dynamic Power Control (DPC) Status section of
the Configuration | WAN | Mod | DPC page provides information on the ongoing DPC state.
Each received LQRM updates this status section; any changes to power are noted between
Target Es/No and Current DPC Delta.