DURKOPP ADLER 967 Operating Instructions Manual page 85

Hide thumbs Also See for 967:
Table of Contents

Advertisement

Maintenance
Operating Instructions 967 - 02.0 - 11/2016
Fig. 42: Setting the operating pressure
(1) - Pressure controller
To set the operating pressure:
1.
Pull the pressure controller (1) up.
2.
Turn the pressure controller until the pressure gage (2) indi-
cates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure controller (1) down.
(2) - Pressure gage
83