DURKOPP ADLER 967 Operating Instructions Manual page 117

Hide thumbs Also See for 967:
Table of Contents

Advertisement

Troubleshooting
Operating Instructions 967 - 02.0 - 11/2016
Code
Possible cause
6364
No valid data on internal
EEprom and no external
EEprom connected
(the internal data structures
are not compatible with
the external data storage
device, emergency
operating features only)
6365
Internal EEprom defective
6366
Internal EEprom defective
and external data not valid
(emergency operating
features only)
6367
Internal EEprom defective
and external EEprom not
connected (emergency
operating features only)
7202
DACextension box boot
error
7203
Checksum error during
update
7212
DA stepper card 1 boot
error
7213
Checksum error occurred
while updating DA stepper
card 2
Remedial action
• Check machine
ID connection
• Switch off the control, wait
until the LEDs are off and
then switch on the machine
again
• Perform software update
• Replace the control
• Replace the control
• Replace the control
• Check connection cables
• Perform software update
• Replace DACextension box
• Check connection cables
• Perform software update
• Replace DACextension box
• Check connection cables
• Perform software update
• Replace DACextension box
• Check connection cables
• Perform software update
• Replace DACextension box
115

Advertisement

Table of Contents
loading

Table of Contents