DURKOPP ADLER 967 Operating Instructions Manual page 120

Hide thumbs Also See for 967:
Table of Contents

Advertisement

118
Code
Possible cause
1010
External synchronizer plug
(Sub-D, 9-pin) not
connected
1011
Encoder Z pulse missing
1012
Synchronizer fault
1052
Sewing motor overcurrent,
internal current increase
>25 A
1053
Sewing motor overvoltage
1054
Internal short circuit
1055
Sewing motor overload
2101
DA stepper card 1
reference run timeout
2103
DA stepper card 1 step
losses
2155
DA stepper card 1 overload • Check for stiff movement
2201
DA stepper card 2
reference run timeout
Remedial action
• Connect cable of external
synchronizer to control,
use correct connection
(Sync)
• Only required for machines
with transmission!
• Switch off the control, use
handwheel to turn, and
switch on the control again
• If error is not corrected,
check encoder
• Replace the synchronizer
• Check selection of class
• Replace the control
• Replace sewing motor
• Replace the encoder
• Check selection of class
• Replace the control
• Replace the control
• Eliminate stiff movement
in the sewing machine
• Replace the encoder
• Replace sewing motor
• Check reference sensor
• Check for stiff movement
• Check reference sensor
Operating Instructions 967 - 02.0 - 11/2016