Mira 415 Installation And User Manual page 35

Pressure balanced shower control
Hide thumbs Also See for 415:
Table of Contents

Advertisement

7.
To check the desired maximum temperature setting has been correctly set, refit
the hub and control knob, turn fully anticlockwise and check the temperature
of the water at the outlet. If still incorrect:
To increase the temperature, reposition the stop one serration
anticlockwise.
To decrease the temperature, reposition the stop one serration clockwise.
Repeat the check as necessary.
Temperature Override Button
Adjustable Temperature Stop
8.
Refit the control knob (with the override button at the bottom), control knob
retaining screw/plastic override stop and concealing cap. Please make sure
the plastic override stop is correctly seated.
This completes the procedure for "Commissioning: maximum temperature
setting".
Adjustable
Temperature Stop
Plastic Override
Stop
35
Cover Shroud
Cover Shroud
Retaining Screws
Control Knob
Control Knob
Retaining Screw
Concealing Cap
Indentations