11. Make the connections to the incoming hot and cold water supply pipes in the
following sequence for each port:-
11.1
Slide the compression nut, then the olive, over the pipe end. If necessary,
sparingly smear liquid jointing on the pipe end and the outside of the
olive.
11.2
Insert pipe end into the opening of the inlet connector then slide the
olive and compression nut into place.
11.3
Finally, carefully tighten, clockwise, the components.
12. Make the connection to the outlet pipe in the following sequence:-
12.1
Place the 'O' seal on to the nipple as shown. Locate the hexagon
towards the shower control outlet port. Screw in clockwise the nipple
using a 12mm A/F hexagon wrench (not supplied).
12.2
Slide the compression nut, then the olive, over the pipe end. If necessary,
sparingly, smear liquid jointing on the pipe end.
12.3
Insert pipe end into the opening of the outlet nipple then slide the olive
and compression nut into place.
12.4
Finally, carefully tighten, clockwise, the components.
12.5
Turn on the water supplies and check the pipework for any leaks!