Mira 415 Installation And User Manual page 29

Pressure balanced shower control
Hide thumbs Also See for 415:
Table of Contents

Advertisement

3.
Follow the shower control installation procedure as for "solid, dry-lined, stud
partition or dry partition wall structures": instructions 6 to 17 inclusive to
complete the installation.
Installation on to the Back face of a shower Cubicle or laminated panel
The building-in depth for the integral wall mounting bracket assembly is 58mm. The
integral wall mounting bracket assembly can be used to install the shower control
into a shower cubicle or laminated panel of between 4 and 21mm. The building-in
depth calculation must include for the final thickness of plaster and tiles.
1.
Follow the shower control installation procedure as for "solid, dry-lined, stud
partition or dry partition wall structures": instructions 1 to 4 inclusive.
2.
Cut a circular hole in the panel measuring 124mm in diameter.
3.
Using the wall mounting bracket as a template, mark the position of the two
smaller diameter fixing holes on the flanges of the bracket. These should be
at an angle of 45°.
230
134
110
146
214
92 A/F
67
Backplate
Wall Mounting
53
Bracket
43
12
38
Ø101
29