70
en | Program and test the control panel
2.
3.
4.
5.
16.2.4

Invisible walk test

An invisible walk test allows you to test both controlled points and 24-hr points. Points
assigned to Point Profiles with the Invisible Point parameter set to Yes.
An invisible walk test includes points meeting the following criteria:
Performing an invisible walk test
1.
2.
3.
4.
5.
2018.07 | 16 | F.01U.287.180
Open Main Menu and then go to the [3] Actions Menu > [3] Test > [1] Walk Test > [1]
Service.
The keypad shows the number of points that remain untested.
To view the list of points, press Enter or View untested points. To scroll through the list
of points, use
/Previous or
When you fault a point (move in front of a motion sensor for example), the keypad emits a
brief tone and shows the point name and information (for example, Area-1 Point-7
Onboard: Short).
Have a point source other than Unassigned
Have a point profile not set to Disabled (must be non-zero)
Have a point profile configured with the point type of 24-Hour, Part On, Interior, or
Interior Follower
Are not service bypassed
Choose a keypad to conduct the test. Ensure that all areas are off (disarmed).
Enter your passcode and press Enter. The keypad shows the number of points that
remain to be tested.
The keypad shows the number of points that remain untested.
To view the list of points, press Enter or View untested points. To scroll through the list
of points, use
/Previous or
When you fault a point (open a door for example), the keypad emits a brief tone and
shows the name.
/Next.
/Next.
Installation Manual
Control Panels
Bosch Security Systems, Inc.