Control Panels
Bell requirements
Use the following Rothenbuhler bell and balanced line modules with the control panel:
Rothenbuhler 5110/4001-42 High Security Bell overview
Callout ᅳ Description
1 ᅳ Self-contained UL listed vibration sensor
2 ᅳ Control panel
3 ᅳ Accessory modules
4 ᅳ High line security module
5 ᅳ 4001-42 Balanced Line Module
6 ᅳ 5110 Bell
7 ᅳ D133 Relay
8 ᅳ Alarm input point
1
Use Terminals 1 through 8. (Select only one.)
2
Use a D113 Battery Lead Supervision Module to supervise the battery connections
Bosch Security Systems, Inc.
Use a separate D8108A for the two 12 V 7 Ah batteries. When using a D122L Dual Battery
Harness, wire the batteries in parallel and connect the harness to the BAT+ and BAT-
terminals of the control panel.
UL Listed Model 5110 Bell
UL Listed Model 4001-42 External Line Balancer
1
0.64 mm (0.25 in)
minimum distance
9
10
13
14
15
1
2
3
4
8
+
11
9
12
Callout ᅳ Description
Installation Manual
Approved applications | en
1
5
7
-
-
+
11
16
9 ᅳ D122/D122L
2
10 ᅳ D126 battery
11 ᅳ D8108A enclosure
12 ᅳ Proximity/control unit
13 ᅳ Normally open (NO)
14 ᅳ Normally closed (NC)
15 ᅳ End-of-line (EOL) resistor
16 ᅳ Safe
2018.07 | 16 | F.01U.287.180