Power supply
6.3 Uninterruptible power supply (UPS)
Example calculation for an M3 motor
Input data
Tag
Value
F
80 N
FR
F
60 N
HC
F
70 N
HO
I
0.1 A
O24
m
180 kg
D
N
5
C
s
0.8 m
D
T
20 s
HC
T
20 s
HO
T
310 s
STBY
v
0.3 m/s
C
A UPS with 600 W and a bridging time of 10 minutes makes approx. 30,000 J available.