Calibration Setting - Furuno FCV-2100 Installation Manual

Fish size indicator
Hide thumbs Also See for FCV-2100:
Table of Contents

Advertisement

3. INITIAL SETTINGS
4. Press and hold the [OK] button for approximately ten seconds.
The service advanced menu for external sounder appears.
5. Select [Shared Settings] to open the [Shared Settings] menu.
6. Select [External Fish Finder] to [On] and select fish finder type (DFF3/ DFF1-
UHD).
Note: The main transceiver's TX trigger setting should be 'Off' while this external
TX trigger is set 'On'.
7. Select the transducer type from menu for DFF3, or set the transducer parameters
for DFF1-UHD
Refer to the procedure for paragraph 3.4.1
8. Select [OK] to close the menu.
3.5

Calibration Setting

The calibration menu allows you to calibrate various settings. You can set the calibra-
tion for main system's transducer and external sounder's transducer.
3.5.1
Calibration for main system transducer
1. Select the [Advanced Settings] icon (
lect the [Advanced Setting] icon (
2. Select [Calibration] from the [System] menu.
The [Calibration] menu appears.
3-10
xx.xx
) from the InstantAccess bar
) from the expanded menu bar.
and se-