Furuno FCV-2100 Installation Manual page 18

Fish size indicator
Hide thumbs Also See for FCV-2100:
Table of Contents

Advertisement

2. WIRING
• NMEA1/2 port: For NMEA (NMEA Ver 1.5, 4800 bps)
• NMEA3: For CIF (4800 bps)
USB device
The USB1/2 ports are available to connect the USB device, such as a USB flush mem-
ory. In order to maintain waterproof rating, this USB ports should be attached at all
times. The USB3 port is used for maintenance only.
2.1.3
Main monitor
The following FURUNO monitors are available for connection to your FCV-2100: MU-
150HD, MU-190 and MU-190HD. You can use an after-market monitor also. The after-
market monitor should have following display resolutions: XGA, SXGA, Full HD or
UXGA or WUXGA.
In order to maintain waterproofing, use a DVI-D/D S-LINK cable to connect the main
monitor to the DVI-D1 port.
Note: The processor unit must be mounted indoors to do this connection because of
reduction in waterproofing.
1. Attach a spacer tube to the DVI cable.
Open the slit on the spacer tube and set the tube to the DVI cable directly behind
the connector. Secure the spacer tube in place with cable ties (supplied).
2. Disassemble the boot cover.
The assembled parts are numbered from 1 to 3. To maintain waterproofing, be
sure the parts are re-assembled in numerical order.
2-4
Secure the spacer tube
in place with cable ties.
Waterproofing gasket
Binding screw
(4 pcs.)
Fixing metal
Binding screw
(2 pcs.)
Spacer tube
Fixing plate
Gasket
Boot cover