Furuno FCV-2100 Installation Manual page 37

Fish size indicator
Hide thumbs Also See for FCV-2100:
Table of Contents

Advertisement

4) Select a transducer model from the
drop-down menu list when the [Setting
Method] is set to [Model].
5) If the [Setting Method] is [Manual], do
the following:
1) Select the output power of the
2) Select [Voltage], then set TX volt-
3) Select [Freq], then set the frequen-
4) Select [Band Width], then set the band width of the transducer.
Procedure for DFF1-UHD
1) Select the [TX Triggering] to [On] to enable the KP control with DFF1-UHD.
Note: The main transceiver's TX trigger setting should be 'Off' while this ex-
ternal TX trigger is set 'On'.
2) Select the [Setting Method] to [Model] or [Manual] for transducer in use.
• Model: for FURUNO or Airmar transducers.
• Manual: for other transducer settings manually.
3) Select the transducer from the drop down list, from among, B265LH,
CM265LH, B275LH-W, CM275LH-W.
7. Click the [OK] button. A window indicates the equipment will restart.
Note: If, for the DFF1-UHD, [Setting Method]=[TD-ID], the TD-ID information is
not received, you are informed that the transducer could not be set and to retry
setting the transducer. Click the [No] button to restart the equipment.
8. Click the [OK] button to restart the equipment.
Note: For the DFF3, if this equipment is not powered within one minute and 30 sec-
onds after powering the DFF3, an error message informs you that you should wait for
this equipment to connect to the DFF3, which takes approx. seven minutes.
3.4.2
[External Fish Finder Window] setting: On
The external echo sounder (fish finder) settings are available on sub monitor window
when the sub monitor is connected. Set the transducer's parameters from sub monitor
window as belows. Suppose the sub monitor is installed and the [External Fish Finder
Window] is set to [On] already.
1. Select the [Windows] icon (
[Sub monitor] icon (
sub monitor.
2. Move the cursor on the sub monitor and right-click to show the [Shared settings]
menu for external sounder setting.
3. Select [Service] to expand the service menu.
The message "Ask your dealer to change service settings." appears.
transducer connected to [TX Pow-
er], from among 1kW, 2kW, 3kW.
age of the transducer.
cy of the transducer.
) to display the echo window of external fish finder on
Transducer
TX Power
Voltage
Freq
Band Width
) from the [InstantAccess] bar
3. INITIAL SETTINGS
, and press the
3-9