Download Print this page
Endress+Hauser Promag 800 L Installation Instruction
Endress+Hauser Promag 800 L Installation Instruction

Endress+Hauser Promag 800 L Installation Instruction

Activating the battery on connection b2 electromagnetic flowmeter

Advertisement

Available languages

Available languages

Quick Links

Installation Instruction
Activating the battery on connection B2
Promag 800 L, W
EA01044D/06/A2/01.12
71206057
Instruction is valid for the following battery packs:
Order-No
Device component
Kit battery, 19Ah
2 × battery pack, 3.6V, 19 Ah
DK5004-1
1 × label battery configuration 
for 2 batteries
Kit battery, 19Ah, 57 Ah
1 × battery pack, 3.6V, 19Ah
DK5004-2
1 × batterie pack, 3.6V, 57Ah
1 × label battery configuration 
for 4 batteries
Kit battery, 57Ah
2 × battery pack, 3.6V, 57Ah
DK5004-3
1 × label battery configuration 
for 6 batteries
!
Note!
• The order number of the battery pack (on the packaging label) can differ from the product number (on the label directly on the battery pack)!
• The order number of the relevant battery pack can be found by entering the product number of the battery pack in the spare parts finder.
• We recommend that the Installation Instructions be kept with the packaging at all times.
look
Order-No
on page 3
DK5004-4
chapter B
on page 3
DK5004-5
chapter C
on page 3
DK5004-6
chapter D
Device component
Kit battery, 19Ah
1 × battery pack, 3.6V, 19Ah
1 × label battery configuration 
for 1 battery
Kit battery, 19Ah, 38Ah, 57Ah
1 × battery pack 3.6V, 19Ah
1 × battery pack 3.6V, 38Ah
1 × battery pack 3.6V, 57Ah
1 × label battery configuration 
GSM for 6 batteries
Kit battery, 19Ah, 57Ah
1 × battery, 3.6V, 19Ah
1 × battery pack 3.6V, 57Ah
1 × label battery configuration 
GSM + power supply for 4 batteries
look
on page 3
chapter E
on page 4
chapter F
on page 4
chapter G

Advertisement

loading

Summary of Contents for Endress+Hauser Promag 800 L

  • Page 1 Installation Instruction Activating the battery on connection B2 Promag 800 L, W EA01044D/06/A2/01.12 71206057 Instruction is valid for the following battery packs: Order-No Device component look Order-No Device component look Kit battery, 19Ah Kit battery, 19Ah 2 × battery pack, 3.6V, 19 Ah on page 3 1 ×...
  • Page 2: Safety Instructions

    – do not connect in potentially explosive atmospheres. environment protected from electrostatic discharge. – only connect to Endress+Hauser service devices. • After removing the electronics cover, there is a risk of electric shock • Observe the instructions for transporting and returning the device as shock protection is removed! ...
  • Page 3 Activating the battery on connection B2 B Configuration 1 for Order-Code DK5004-1 Configuration of batteries Connectors Number of batteries Battery usage Backup power supply for the measuring device: B1 has been switched on by the manufacturer and needn‘t to be considered. Power supply for the measuring device Power supply for the GSM/GPRS modem A0017127...
  • Page 4 Activating the battery on connection B2 F Configuration 5 for Order-Code DK5004-5 Configuration of batteries Connectors Number of batteries Battery usage Backup power supply for the measuring device: B1 has been switched on by the manufacturer and needn‘t to be considered. Power supply for the measuring device Power supply for the GSM/GPRS modem: B3 has been switched on by the manufacturer and needn‘t to be considered.
  • Page 5: Aktivieren Der Batterie An Anschluss B2

    Einbauanleitung Aktivieren der Batterie an Anschluss B2 Promag 800 L, W EA01044D/06/A2/01.12 71206057 Die Einbauanleitung ist für folgende Batteriesets gültig: Bestell-Nr. Gerätekomponente Siehe Bestell-Nr. Gerätekomponente Siehe Batterieset, 19Ah Batterieset, 19Ah Seite 3 Seite 3 DK5004-1 2 × Batterie-Pack, 3.6V, 19 Ah DK5004-4 1 ×...
  • Page 6 • Die in der Betriebsanleitung aufgeführten Hinweise zum Transport • Nach Entfernen der Elektronikabdeckung: Stromschlaggefahr durch und zur Rücksendung beachten. aufgehobenen Berührungsschutz!  • Bei Fragen kontaktieren Sie bitte Ihre zuständige Endress+Hauser Messgerät ausschalten, bevor interne Abdeckungen entfernt werden. Serviceorganisation. • Änderungen am Messgerät sind nicht zulässig.
  • Page 7 Aktivieren der Batterie an Anschluss B2 B Konfiguration 1 für Bestellcode DK5004-1 Konfiguration Batterien Anschlussstecker Anzahl Batterie Verwendung der Batterie(n) Sicherung der Versorgung des Messgerätes (Back-up): B1 ist bereits vom Herstellerwerk aus eingeschaltet und muss nicht berücksichtigt werden. Versorgung des Messgerätes Versorgung GSM/GPRS-Modems A0017127 C Konfiguration 2 für Bestellcode DK5004-2...
  • Page 8 Aktivieren der Batterie an Anschluss B2 F Konfiguration 5 für Bestellcode DK5004-5 Konfiguration Batterien Anschlussstecker Anzahl Batterie Verwendung der Batterie(n) Sicherung der Versorgung des Messgerätes (Back-up): B1 ist bereits vom Herstellerwerk aus eingeschaltet und muss nicht berücksichtigt werden. Versorgung des Messgerätes Versorgung GSM/GPRS-Modems: B3 ist bereits vom Herstellerwerk aus eingeschaltet und muss nicht berücksichtigt werden.