DVC6200 Digital Valve Controller
2
NOTE:
APPLY LUBRICANT
1
W9702
Figure 2-5. Mounting the Fisher 67CFR Regulator on a FIELDVUE DVC6200 Digital Valve Controller

Mounting Fisher 67CFR Filter Regulator

A 67CFR filter regulator, when used with a DVC6200
digital valve controller, can be mounted one of three
ways.
Integral-Mounted Regulator
Refer to figure 2-5. Lubricate an O-ring and insert it in
the recess around the SUPPLY connection on the
digital valve controller. Attach the 67CFR filter
regulator to the side of the digital valve controller.
Thread a 1/4-inch socket-head pipe plug into the
unused outlet on the filter regulator. This is the
standard method of mounting the filter regulator.
14
67CFR
1
O-RING
SUPPLY CONNECTION
Yoke-Mounted Regulator
Mount the filter regulator with two cap screws to the
pre-drilled and tapped holes in the actuator yoke.
Thread a 1/4-inch socket-head pipe plug into the
unused outlet on the filter regulator. No O-ring is
required.
Casing-Mounted Regulator
Use the separate 67CFR filter regulator casing
mounting bracket provided with the filter regulator.
Attach the mounting bracket to the 67CFR and then
attach this assembly to the actuator casing. Thread a
1/4-inch socket-head pipe plug into the unused outlet
on the filter regulator. No O-ring is required.
CAP SCREWS
September 2010