13
Zigzag stitch motion
.05.08
Requirement
When the needle bar is at tdc coming from the right bdc (hole 2), the needle bar must not
move laterally when the zigzag stitch adjustment lever is moved back and forth.
Fig. 13 - 09
Adjust zigzag stitch eccentric 1 (screws 2) in accordance with the requirement, taking
care that the zigzag eccentric 1 is at a distance of approx. 5 mm from the inside right wall
of the case.
4
3
1
2
5
5 mm
1
2
Adjustment
13 - 10