Mounting/Checking The Start Inhibitor - Pfaff 2438 plusline Instruction Manual

Table of Contents

Advertisement

8

Mounting/checking the start inhibitor

.04
Fig. 8 - 07
Mounting the start inhibitor
For machines delivered without a table, the plate 1 from the accessories should be
mounted under the table top, so that the switch lug 2 is resting on plate 1 when the
sewing head is in an upright position.
After loosing the screws 4, adjust switch 3 so that the switch is off when the sewing head
is tilted over and activated by switch lug 2 when the sewing head is upright.
Checking the start inhibitor
Switch the machine on at the main switch and tilt it over.
The error message "E009" must appear on the control panel.
If the message does not appear, check the setting of switch 3.
Set the sewing head upright and acknowledge the error message by pressing the TE/
Speed key. The machine is ready for operation again.
Mounting and commissioning the machine
1
81-093
4
ERROR
E009
PRESS TE-SPEED
2
3
81-092
8 - 5