Touchscreen Board Cable - HP Spectre x2 Maintenance And Service Manual

12 detachable pc (model numbers 12-c000 through 12-c099)
Hide thumbs Also See for Spectre x2:
Table of Contents

Advertisement

1.
Release the Mylar shield (1) that secures the solid-state drive to the system board.
2.
Remove the Phillips PM2.0×2.5 screw (2) that secures the drive to the system board. (The solid-state
drive tilts up.)
3.
Remove the solid-state drive (3) by pulling it away from the connector.
NOTE:
Reverse this procedure to install the solid-state drive.

Touchscreen board cable

Description
Touchscreen board cable (includes double-sided adhesive)
Before removing the Touchscreen board cable, follow these steps:
1.
Shut down the tablet. If you are unsure whether the tablet is off or in Hibernation, turn the tablet on,
and then shut it down through the operating system.
2.
Disconnect all external devices connected to the tablet.
3.
Disconnect the power from the tablet by first unplugging the power cord from the AC outlet, and then
unplugging the AC adapter from the tablet.
4.
Remove the display panel assembly (see
5.
Remove the bottom bezel (see
6.
Remove the battery (see
Remove the Touchscreen board cable:
1.
Release the ZIF connector (1) to which Touchscreen board cable is connected, and then disconnect
the Touchscreen board cable from the system board.
Solid-state drives are designed with notches to prevent incorrect insertion.
Bottom bezel on page
Battery on page
Display panel assembly on page
24).
25).
Component replacement procedures
Spare part number
924172-001
20).