Section 6
Functions
Functions
Operation Mode
The Reader/Writer has two operation modes: Run Mode, and Safe Mode.
You can use the control signal to the Reader/Writer connector to change between these modes.
 Run Mode
When you connect the control signal to the 24-VDC side of the power supply and turn ON the power
supply, the Reader/Writer will start in Run Mode.
Operation is performed in the modes specified in the commands from the host device and the results
are returned to the host device as responses.
 Safe Mode
When you connect the control signal to the 0-VDC side of the power supply and turn ON the power
supply, the Reader/Writer will start in Safe Mode. The Safe Mode is used when you do not remember
the IP address that is set in the Reader/Writer. In Safe Mode, the Reader/Writer will start with the
following IP settings.
IP address: 192.168.1.200
Subnet mask: 255.255.255.0
RFID System