Section 2
System Configuration
 The computer is connected to monitor the results of communications diagnostics
Reader/Writer
(V680S-HMD6 -PNT)
(V680 Series and V680S Series)
Connect the Ethernet Cable to a host device (e.g., Switching Hub or PLC) that supports STP and ground the host device to
100 Ω or less.
Always use a Switching Hub on any network where cyclic data exchanges are used.
RFID System
54
User's Manual
(PROFINET)
RF Tag
Ethernet Cable
Ethernet Cable (Max. length: 100 m)
(Recommended: XS5W-T42 - MC-K from OMRON)
Power Cable
(Recommended: XS5F-D42 - 80-F from OMRON)
The system requirements to use the Web browser are as follows:
Internet Explorer 7 or higher running on Windows XP or Windows 7
JRE Version 8.0 or higher
For details, refer to Section 8 Browser Interface.
p.181
Computer to monitor the
Host device
results of communications
(e.g., PLC)
diagnostics
Switching Hub
(Recommended: W4S1-05C Switching Hub
from OMRON)
24-VDC power supply
Computer