 RF Analyzer Diagnostic Log File
You can click the Export Button on the RF Analyzer View to download the diagnostic log stored in the
Reader/Writer to a computer and save it as a CSV file. The following information is included in the
diagnostic log file. You can use it to check more detailed information than you can on the web browser
displays.
Item name
No
Numbers are assigned from 1 to 2,048.
The larger the number, the more recent the information.
Time Stamp
The Reader/Writer operating time when the diagnostic information was registered.
Command
The command type that was executed when the diagnostic information was registered.
Response Result
The communications result is displayed. "Warning" is displayed if the communications diagnostic
result shows an unstable communication.
• Normal: Normal
• Warning: Unstable
• Other: Error type name
Diagnostic Result
The communications diagnostic result is displayed.
• Good: Stable
• Output level low: Low send power
• Receiving level low: Low receive power
• Noise level high: Excessive ambient noise level
• Signal-Noise ratio low: Low signal-to-noise ratio
• N/A: Communications error
Output Level
The send power level to the RF Tag is given between 0 and 10. The higher the value, the better
the conditions. (If the level is 9 or lower, the Reader/Writer will determine that the communication
was unstable.)
Receiving Level
The receive power level from the RF Tag to the Reader/Writer is given between 0 and 10. The
higher the value, the better the conditions. (If the level is 9 or lower, the Reader/Writer will
determine that the communication was unstable.)
Noise Level
The ambient noise level around the Reader/Writer is given between 0 and 10. The lower the
value, the better the conditions. (If the level is 5 or higher, the Reader/Writer will determine that
the communication was unstable.)
Signal Level
The overall level combining Output Level and Receiving Level is given between 0 and 10. The
higher the value, the better the conditions.
Tag ID
The Tag ID of the RF Tag for which communication diagnostic was performed is given.