Omron V680S-HMD63-PNT User Manual page 152

V680s series, profinet, reader/writer
Hide thumbs Also See for V680S-HMD63-PNT:
Table of Contents

Advertisement

Section 7
Host Communications Specifications
V680S Command Details
READ ID
This command reads the ID code of the RF Tag in the communications field.
 Command Area
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
 Response Area
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespData/Response Data
ID Data
 Execution Example
Reading the ID Data from the RF Tag
Command Area
Memory offset
Data name
+2
CmdCode
+4
CmdParam1
+6
CmdParam2
RFID System
150
User's Manual
(PROFINET)
Signal/data
Data type
WORD
WORD
WORD
Signal/data
Data type
WORD
WORD
WORD
STRUCT
ARRAY[]
OF BYTE
Byte +0
Byte +1
0
0
0
1
0
0
0
0
0
0
0
0
Size
2 bytes
0001 hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
Size
2 bytes
Error code
2 bytes
Device information
2 bytes
Communications diagnostics result
---
---
ID data read from the RF Tag (always 8 bytes)
8 bytes
RF Tag UID
Response Area
66554433221105E0
Memory offset
+2
ErrCode
+4
RespInfo1
+6
RespInfo2
+8
RespData[0-1]
+10
RespData[2-3]
+12
RespData[4-5]
+14
RespData[6-7]
Function
Function
Data name
Byte +0
Byte +1
0
0
0
0
0
0
0
0
0
6
6
5
4
4
3
2
2
1
0
5
E
0
0
0
5
3
1
0