Status Messages

Status messages are generated automatically and appear in the fourth
(bottom) line of the display as shown.
A. The first part of the status line indicates the CONTROL POINT of
the drive.
B. The center part of the status line indicates the REFERENCE
LOCATION.
C. The last part of the status line gives the present DRIVE STATUS.
The table below defines the status massage display words.
D IS PL AY
W O R D
C O N T R O L PO IN T
AU T O
H AN D
O F F
R EF ER E N C E L O C AT IO N
R EM .
LO C A L
D R IV E ST AT U S
R U N N IN G
R AM PIN G
AU T O R A M P
SLE EP .B ST
SLE EP
ST A R T D E L
94
T he drive is in A uto m ode, w hich m eans that R un/S top control is carried out
via the control term inals and/or serial com m unication.
T he drive is in H and m ode, w hich m eans that R un/S top control is carried out
via the keys on the keypad
O F F/ST O P is activated either by m eans of the keypad, or by the digital
inputs H and S tart and Auto S tart, both being a logic '0.'
If R EM O T E has been selected, the reference is set via the control term inals
or via serial com m unication.
If LO C A L has been selected, the reference is set via the [+] and [-] k eys on
the keypad.
T he m otor speed now corresponds to the resulting reference.
T he output frequency is changing.
Param eter 208, Autom atic R am p, is enabled. T he drive is attem pting to
avoid a trip from overvoltage by extending its decel ram p tim e.
T he boost function in param eter 406, B oost Setpoint, is enabled. T his
function can only be enabled in C losed Loop operation.
WARNING
!
U nintended S tart!
W hen in Sleep m ode, m otor m ay restart at any tim e without w arning. The
drive, m otor, and any driven equipm ent m ust be in operational readiness.
Failure to be in operational readiness could result in death, serious injury, or
equipm ent and property dam age.
T he energy saving function in param eter 403, S leep M ode Tim er, is enabled.
T his status m essage shows that at present the m otor has been stopped by
sleep m ode. It can restart autom atically.
!
WARNING
U nintended S tart!
W hen in Start Delay m ode, m otor m ay restart at any tim e w ithout warning. The
drive, m otor, and any driven equipm ent m ust be in operational readiness.
Failure to be in operational readiness could result in death, serious injury, or
equipm ent and property dam age.
A start delay tim e has been program m ed in param eter 111, S tart D elay.
W hen the delay has passed, the drive w ill start and ram p up to the reference
frequency.
80.0% 5.08A 2.1HP
40.0 Hz
AUTO REM.
HAND
LOCAL