Advertisement

5.3

(E) Environment setting parameters

Purpose
To set a limit for the reset function.
To shut off output if the operation panel
disconnects.
To force deceleration to a stop on the
operation panel.
To select the display language of the
parameter unit
To control the buzzer (beep) of the parameter
unit or LCD operation panel
To adjust the LCD contrast of the parameter
unit
To select the command for the direction of
rotation to be assigned to the RUN key on the
operation panel
To set the frequency using the UP/DOWN key
on the operation panel.
To disable the operation panel.
To prevent parameter rewriting
To restrict access to parameters with a
password
To reduce the motor noise and EMI
5.3.1
Reset selection / Disconnected PU detection / PU
stop selection
The acceptance of reset command, the inverter operation in the event of detection of the PU (operation panel / parameter unit)
disconnected, and the acceptance of stop command from the PU (PU stop function) can be selected.
Pr.
Name
Reset selection /
Disconnected PU
75
detection / PU stop
selection
E100
Reset selection
Disconnected PU
E101
detection
E102
PU stop selection
The parameters above do not return to their initial values even if Parameter clear or All parameter clear is executed.
Reset selection /
Disconnected PU detection
/ PU Stop selection
PU display language
selection
PU buzzer control
PU contrast adjustment
RUN key rotation direction
selection
Operation panel operation
selection
Parameter write disable
selection
Password
PWM carrier frequency
changing
Initial
Setting range
value
14
0 to 3, 14 to 17
0
0
1
0
0
1
0
0
1
Parameter to set
P.E100 to P.E102
Pr.75
P.E103
Pr.145
P.E104
Pr.990
P.E105
Pr.991
P.E202
Pr.40
P.E200
Pr.161
P.E400
Pr.77
P.E410, P.E411
Pr.296, Pr.297
P.E600, P.E601
Pr.72, Pr.240
Description
In the initial setting, the reset command can always be
input, the operation continues when the PU is
disconnected, and the PU stop function is enabled in any
operation mode.
The reset command can always be input.
The reset command can be input only when the protective
function is activated.
Operation continues even when the PU is disconnected.
The inverter output is shut off when the PU is disconnected.
Only in PU operation mode, the inverter decelerates to a
stop by pressing the STOP key on the PU.
The inverter decelerates to a stop by pressing the STOP
key on the PU in any operation mode of the PU, External,
or Network.
5.3 (E) Environment setting parameters
2
Refer to
2
page
85
3
87
4
87
88
5
88
6
88
7
89
90
8
92
9
10
85
5. PARAMETERS