• Parameters
Pr.
Register
41000 to
Refer to the parameter list (page
0 to 999
41999
page
Terminal 2 frequency setting bias
C2 (902)
41902
(frequency)
Terminal 2 frequency setting bias
42092
(analog value)
C3 (902)
Terminal 2 frequency setting bias
43902
(terminal analog value)
Terminal 2 frequency setting gain
125 (903)
41903
(frequency)
Terminal 2 frequency setting gain
42093
(analog value)
C4 (903)
Terminal 2 frequency setting gain
43903
(terminal analog value)
Terminal 4 frequency setting bias
C5 (904)
41904
(frequency)
Terminal 4 frequency setting bias
42094
(analog value)
C6 (904)
Terminal 4 frequency setting bias
43904
(terminal analog value)
Terminal 4 frequency setting gain
126 (905)
41905
(frequency)
Terminal 4 frequency setting gain
42095
(analog value)
C7 (905)
Terminal 4 frequency setting gain
43905
(terminal analog value)
• Fault history
Register
40501
Fault record 1
40502
Fault record 2
40503
Fault record 3
40504
Fault record 4
40505
Fault record 5
40506
Fault record 6
40507
Fault record 7
40508
Fault record 8
• Product profile
Register
44001
Model (1st and 2nd characters)
44002
Model (3rd and 4th characters)
44003
Model (5th and 6th characters)
44004
Model (7th and 8th characters)
44005
Model (9th and 10th characters)
44006
Model (11th and 12th characters)
44007
Model (13th and 14th characters)
44008
Model (15th and 16th characters)
44009
Model (17th and 18th characters)
44010
Model (19th and 20th characters)
44011
Capacity (1st and 2nd characters) Read
44012
Capacity (3rd and 4th characters)
44013
Capacity (5th and 6th characters)
NOTE
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
Name
Read/Write
72) for parameter names.
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Definition
Read/write
Read/Write
Read
Read
Read
Read
Read
Read
Read
Definition
Read/write
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read/write
The parameter number + +41000 is the register number.
Analog value (%) set in C3 (902)
Analog value (%) of the voltage (current) applied to
terminal 2
Analog value (%) set in C4 (903)
Analog value (%) of the voltage (current) applied to
terminal 2
Analog value (%) set in C6 (904)
Analog value (%) of the current (voltage) applied to
terminal 4
Analog value (%) set in C7 (905)
Analog value (%) of the current (voltage) applied to
terminal 4
Being 2 bytes in length, the data is stored as H00○○.
Refer to the lowest 1 byte for the error code. (For details on
error codes, refer to
page
Performing write using the register 40501 batch-clears the
faults history.
Set any value as data.
The inverter model can be read in ASCII code.
"H20" (blank code) is set for blank area.
Example) FR-CS84:
H46,H52,H2D,H43,H53,H38,H34
The capacity in the inverter model can be read in ASCII code.
Data is read in increments of 0.1 kW, and rounds down to 0.01
kW increments.
"H20" (blank code) is set for blank area.
Example) 0.75K: "
7" (H20, H20, H20, H20, H20, H37)
5.11 (N) Communication operation parameters
Remarks
Remarks
210.)
Remarks
5. PARAMETERS
2
2
3
4
5
6
7
8
9
10
191