Vertical Venting With Three (3) 90; Elbows - Regency Bellavista B36X Owners & Installation Manual

Medium dv gas fireplace
Hide thumbs Also See for Bellavista B36X:
Table of Contents

Advertisement

One 90
elbow = Two 45
o
Option
V
H
A)
0' Min.
1' Max. 1' Min.
B)
1' Min.
2' Max. 3' Min.
C)
2' Min.
2' Max. 5' Min.
D)
3' Min.
2' Max. 7' Min.
E)
4' Min.
3 Max. 9' Min.
F)
5' Min.
4' Max. 10' Min. 7' Max.
G)
6' Min.
5' Max. 11' Min. 8' Max.
H)
7' Min.
6' Max. 12' Min. 9' Max.
Vent Restrictor - Full Open/ No Restrictor Installed
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.
One 90
elbow = Two 45
o
Option
V
H + H1 V + V1
A)
0' Min.
2' Max. 2' Min.
B)
1' Min.
2' Max. 3' Min.
C)
2' Min.
3' Max. 4' Min.
D)
3' Min.
4' Max. 6' Min.
E)
4' Min.
5' Max. 7' Min.
F)
5' Min.
6' Max. 8' Min.
G)
6' Min.
7' Max.
H)
7' Min.
8' Max. 10' Min.
Vent Restrictor Set at 2" Opening
Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994
Regency Bellavista™ B36X Gas Fireplace
HORIZONTAL VENTING WITH THREE (3) 90
(RIGID PIPE 4" X 6 - 5/8")
H1

elbows.

o
V + V1
H + H1
With these options,
max. total pipe length
2' Max.
is 30 feet with min. of
3' Max.
12 feet total vertical
4' Max.
and max. 9 feet total
5' Max.
horizontal.
6' Max.
Please note min. 1
foot between 90
elbows is required.

VERTICAL VENTING WITH THREE (3) 90

(RIGID PIPE 4" X 6 - 5/8")
elbows.
o
With these options, max.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
elbows is
o
9' Min.
required.
O
ELBOWS
H
V1
o
ELBOWS
O
V1
H1
INSTALLATION
V
V
H
29