Vertical Venting With Two (2) 90 Elbows; Vertical Venting With Three (3) 90 Elbows - Regency P36D-LP10 Owners & Installation Manual

P36d zero clearance direct vent gas fireplace
Hide thumbs Also See for P36D-LP10:
Table of Contents

Advertisement

VERTICAL VENTING WITH TWO (2) 90
One 90
elbow = Two 45
o
Option
V
H
A)
0' Min.
2' Max. 1' Min.
B)
1' Min.
4' Max. 3' Min.
C)
2' Min.
5' Max. 4' Min.
D)
3' Min.
6' Max. 5' Min.
E)
4' Min.
7' Max. 6' Min.
F)
5' Min.
8' Max. 7' Min.
Lengths do not include elbow indicated.
VERTICAL VENTING WITH THREE (3) 90
One 90
elbow = Two 45
o
Option
V
H + H1 V + V1
A)
0' Min.
2' Max. 2' Min.
B)
1' Min.
2' Max. 3' Min.
C)
2' Min.
3' Max. 4' Min.
D)
3' Min.
4' Max. 6' Min.
E)
4' Min.
5' Max. 7' Min.
F)
5' Min.
6' Max. 8' Min.
G)
6' Min.
7' Max.
H)
7' Min.
8' Max. 10' Min.
Lengths do not include elbow indicated.
ELBOWS
O
elbows.
o
V + V1
With these options, max. total
pipe length is 30 feet with min.
of 7 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
elbows is
o
required.
ELBOWS
O
elbows.
o
With these options, max.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
elbows is
o
9' Min.
required.
V1
V1
H1
®
Regency
P36D-10 Zero Clearance Direct Vent Gas Fireplace
installation
V
H
V
H
|
29
|
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36d-ng10

Table of Contents