Regency Bellavista B36X Owners & Installation Manual page 40

Medium dv gas fireplace
Hide thumbs Also See for Bellavista B36X:
Table of Contents

Advertisement

INSTALLATION
12) Turn control knob to the "OFF" position.
13) Remove the black protection cap by hand from the hi-low knob
(Fig.1).
Cap
14) Insert a 5/32" or 4mm Allen wrench into the hexagonal key-way
of the screw (Fig. 2), rotate it counter-clockwise until it is free and
extract it.
15) Check that the screw is clean and if necessary remove dirt.
16) Flip the screw (Fig. 3).
Red O-ring
17) Using the Allen wrench as shown in
Fig.4, rotate the screw clockwise until
snug, do not overtighten.
WARNING!
Do not over tighten the screw.
Recommended to
grip the wrench by the short side.
40
18) Verify that if the conversion is from NG to LPG, the screw must
19) Re-assemble the black protection cap (Fig. 6).
Fig. 1
20) Reverse steps 8 - 1.
Fig.2
21) Attach the label "This unit has been converted to LPG" near or on
22) Replace yellow "NG" label with red "LPG" label.
Fig.3
Fig.4
be re-assembled with the red o-ring visible (Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
Fig. 6
top of the serial # decal.
WARNING!
Also check that the pilot and main
burner injectors are appropriate for
the gas type.
Regency Bellavista™ B36X Gas Fireplace