Regency Bellavista B41XT-NG1 Owners & Installation Manual

Regency gas fireplace
Table of Contents

Advertisement

Quick Links

Regency Bellavista
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-914
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
B41XT
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Owners &
Installation Manual
MODELS: B41XT-NG1
B41XT-LP1
www.regency-fi re.com
04/11/11

Advertisement

Table of Contents
loading

Summary of Contents for Regency Bellavista B41XT-NG1

  • Page 1 Owners & B41XT Regency Bellavista ™ Installation Manual Gas Fireplace MODELS: B41XT-NG1 B41XT-LP1 www.regency-fi re.com WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi re or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The Bellavista™ B41XT has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The Bellavista™ B41XT has been approved by Warnock Hersey/ Intertek for both safety and effi...
  • Page 3: Manufactured Mobile Home Requirements

    This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. Ensure that structural members are not cut or weakened during installation. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 4: Table Of Contents

    Unit Installation with Horizontal Termination ....31 WARRANTY 5" x 8" venting ............31 Unit Installation with Horizontal Termination ....32 The Warranty: Limited Lifetime ........63 Unit installation with Vertical Termination ....33 Gas Line Installation ............33 Pilot Adjustment ............34 Regency Bellavista™ B41XT Gas Fireplace...
  • Page 5: Safety Label

    WN # 16603 MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE. Minimum Clearances to Combustibles / NATURAL GAS: Model B41XT-NG1 APPAREIL FONCTIONNANT AU NATURAL GAS Degagement Minimum De Materiaux Combustibles CONCU POUR ETRE POELE: Mod le B41XT NG1 é...
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 7: Dimensions

    DIMENSIONS UNIT DIMENSIONS 23-1/4” (591mm) 13-3/16” (335mm) 46-11/16” (1186mm) 38-3/16” (970mm) 41-11/16” (1059mm) 43” (1092mm) 35” (889mm) 1” (25mm) Regency Bellavista™ B41XT Gas Fireplace...
  • Page 8: Installation

    SHOULD STAY AWAY TO AVOID BURNS 8) To prevent injury, do not allow anyone who is OR CLOTHING IGNITION. unfamiliar with the operation to use the fi replace. 9) Wear gloves and safety glasses for protection while doing required maintenance. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 9: Installation Checklist

    Fan Installation (Optional) h. Light Installation (Optional) i. Louvers / Flush Panels j. Full Screen Arch Door k. Finishing Trim (Optional) 8) Final check. Diagram 1 Flat on Wall Flat on Wall Corner Recessed into Wall/Alcove Corner Regency Bellavista™ B41XT Gas Fireplace...
  • Page 10: Clearances

    NOTE: A 16" deep non-combustible hearth pad is recommended for hardwood fl ooring and carpet. Alcove Minimum Vent Clearances to Combustibles Horizontal Top 3" (76mm) Horizontal Side 2 " (51mm) Horizontal Bottom 2" (51mm) Vertical Vent 2" (51mm) Regency Bellavista™ B41XT Gas Fireplace...
  • Page 11: Mantel Clearances

    7” Non-combustible 1" Header (steel stud) on edge 13-1/2” Non-combustible Standoff Top of Side View Fireplace Opening To Floor Mantel Clearances B41XT From Top of 35-1/4" 23-1/4" 19-1/2" 15" Fireplace Opening (895mm) (895mm) (495mm) (381mm) Regency Bellavista™ B41XT Gas Fireplace...
  • Page 12: Mantel Leg Clearances

    (Measured from side of Fireplace Opening) 4” 7” Allowable mantel leg projection. NON-COMBUSTIBLE REQUIREMENTS Non-combustible Header (steel stud) 48-3/4" on edge (1238mm) Non-combustible Non-combustible Material 41-3/4" (1060mm) 47-1/4" (1200mm) Framing Min. 3-1/2” Min. 3-1/2” (89mm) (89mm) Regency Bellavista™ B41XT Gas Fireplace...
  • Page 13: Framing

    ** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth. Non-Combustible Drywall, Wood Header (or other facing) (steel stud) on edge Non-Combustible Header (steel stud) on edge Non-Combustible Facing 11" (279mm) dia. Hole through wall Vent. Top Vent Rear Vent Opening for gas connection Regency Bellavista™ B41XT Gas Fireplace...
  • Page 14: Finishing

    Finishing material - Material thicker than 1-1/4" Full Screen J-style Trim Door or metal corner bead may be used to finish these edges Diagram 2 " Diagram 5 Diagram 3: Shown with optional Finishing Trim Regency Bellavista™ B41XT Gas Fireplace...
  • Page 15: Unit Assembly Prior To Installation

    1/2" / 13mm 7/8" / 22mm 1-1/4" / 32mm "C" Screw Position: Top Facing Support is reversed For a facing material depth of 1-1/4" (32mm), for “C” hole position the top facing support must be reversed. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 16: Conversion To Top Vent

    2) From inside the fi rebox, remove the baffl e plate by removing 4 screws - remove top front screw fi rst. 6) From the outside top of the fi rebox - slide the square piece of insulation out and discard. Baffl e Plate Regency Bellavista™ B41XT Gas Fireplace...
  • Page 17 All 4 screws must be used. View Front of Firebox 13) Set vent restrictor accordingly - see next page. 14) From inside the fi rebox, re-install the baffl e plate from step 2. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 18: Venting Introduction

    6) From inside the fi rebox, install the baffl e plate with 4 - 1/4" x 1/2 " AT 1-1/2” screws. Ensure all screws are tightly secure, but do not over tighten. Diagram 1 Baffl e Plate Diagram 3 Regency Bellavista™ B41XT Gas Fireplace...
  • Page 19: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency Bellavista™ B41XT Gas Fireplace...
  • Page 20: 5" X 8" Rigid Pipe

    5DWS Offset Support 58DVA-ES - N/A from FPI 5DT-OS Wall Thimble-Black 58DVA-WT 5DT-WT 5DWT TE-5DE90 Wall Thimble Support/Ceiling Support 58DVA-DC TE-5DE90B - N/A from FPI Firestop Spacer 58DVA-FS 5DT-FS 5DFS Trim Plate-Black 58DAV-WFS 5DT-TP 5DCP Regency Bellavista™ B41XT Gas Fireplace...
  • Page 21 1 foot of run towards the termination. 36” (914mm) 29-13/16” (757mm) 39-7/16” (1002mm) Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. 48” (1219mm) 38-1/4” (972mm) 47-7/8” (1216mm) Regency Bellavista™ B41XT Gas Fireplace...
  • Page 22: Venting Arrangements For Horizontal Terminations

    FLEX VENT OR RIGID PIPE 5" X 8" The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.
  • Page 23: Horizontal Terminations

    Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.
  • Page 24: Rigid Pipe 5" X 8

    Vinyl Siding Standoff (Optional) Horizontal Termination Wall Thimble Pipe Length 90 Elbow Rigid Pipe Adaptor Pipe Length Rigid Pipe Adaptor IMPORTANT Must use Rear Venting Defl ector packaged with unit in rear vent horizontal termination applications. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 25: Astrocap Xl & Rigid Rear Vent Kit

    90ml MillPac 948-128 3” Vinyl Siding Standoff (Optional) Astrocap 85-3/16” Wall Thimble Pipe Length 45 elbow Rigid Pipe Adaptor IMPORTANT Must use Rear Venting Defl ector packaged with unit in rear vent horizontal termination applications. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 26: Venting Arrangements

    A wall thimble is mandatory for all horizontal terminations due to high temperatures. Horizontal (Feet) 18 18 18 18 Restrictor 1-1/2” Open Set 3 Restrictor 2-1/2” Open Set 2 Restrictor 3-1/2” Open Set 1 47-1/2" (1207mm) Minimum Height Requirement Regency Bellavista™ B41XT Gas Fireplace...
  • Page 27: Rigid Pipe Venting Systems

    ® Direct Vent Pro, ICC Excel and Selkirk Direct-Temp. AstroCap XL is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 28: Horizontal Terminations

    6' Min. 5' Max. 11' Min. 8' Max. elbows is required. 7' Min. 6' Max. 12' Min. 9' Max. No Vent Restrictor Installed Lengths do not include elbow indicated. Must use rigid pipe adaptor #770-994. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 29 Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting to 3-1/2" opening, 2-1/2"opening and to 1-1/2" opening. Note: Must use optional fl ue adapter when using Rigid Pipe (Part # 770-994). Regency Bellavista™ B41XT Gas Fireplace...
  • Page 30: Vertical Terminations

    6' Max. 8' Min. between 90 elbows is 6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. No Vent Restrictor Installed Lengths do not include elbow indicated. Must use rigid pipe adaptor #770-994 Regency Bellavista™ B41XT Gas Fireplace...
  • Page 31: Unit Installation With Horizontal Termination

    4) Level the fi replace and fasten it to the framing using nails or screws through the top and side nailing strips. Diagram 7 Diagram 2 IMPORTANT Diagram 1 Must use Rear Venting Defl ector packaged with unit in rear vent horizontal termination applications. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 32: Unit Installation With Horizontal Termination

    Apply Mill Pac or high temperature silicone to the outer fl ex pipe and slip it over Vinyl Siding the outer fl ue collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 Wall Thimble Screws screws. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 33: Unit Installation With Vertical Termination

    Important: Always check for gas leaks with a vent height may solve the problem. soap and water solution or gas leak detector. Do not use open fl ame for leak testing. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 34: Pilot Adjustment

    1) Gas on/off knob 2) Manual high/low adjustment 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point Regency Bellavista™ B41XT Gas Fireplace...
  • Page 35: Brick Panel Installation

    fi rebox wall (left side shown). Position the left brick panel in place and secure with the brick panel clip and screw removed from the fi rebox as shown below. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 36: Optional Stainless Steel / Black Enamel

    fi rebox. See diagram below. panel is centered when installed. Install the right side panel - secure with panel clip and 1 screw. See step 3. Top Panel Bracket Back Panel Right Side Panel Regency Bellavista™ B41XT Gas Fireplace...
  • Page 37 Top panel bracket shown installed with Stainless Steel Panels 5) Slide top panel under the top of the back and right side panels as shown below. 6) Install left side panel - repeat step 4. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 38: Log Set Installation

    2) Spread vermiculite along the base of the fi rebox. 4) Place Log F on the right side of the burner, directly in front of Log A. Position Log F so it fi ts into the pin on the burner as shown below. Vermiculite Regency Bellavista™ B41XT Gas Fireplace...
  • Page 39 Position Log G so it fi ts into the pin on the burner as shown below. 10) Slide the right side of Log H back until it touches the tab on the burner shown below. Tab on Burner Back of Log H Regency Bellavista™ B41XT Gas Fireplace...
  • Page 40 13) Position Log B on top of Log A. Log B fi ts into the pin in Log A. Ensure Log B sits upright 90 degrees with the left side of the log resting on the notch in Log E. See next 2 diagrams. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 41 19) Test fi re to ensure proper lighting (make sure fl ame fl ows smoothly from one end of the burner to the other). If there is any fl ame hesitation, check that area for any blockage of the burner ports. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 42: Optional Wall Thermostat

    1) The DC Sparker requires 1 AA battery to operate. Note: Pilot cannot be lit without battery in place. 2) Remove the battery cover from the DC Sparker. 3) Insert 1 AA battery, as illustrated below. Replace the battery cover. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 43: Optional Fan Installation

    5) Connect the Red wire onto the right side terminal of the fan motor, Connect the red wire into the grommet and push grommet into the fan assembly housing. BLACK 8) Connect and secure fan ground cable to ground lug. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 44 IMPORTANT: edges. These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming the fan blades and housing using a soft brush nozzle. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 45: Aeration Adjustment

    ELECTRICAL WORK MUST BE Light PERFORMED BY A QUALIFIED Switch Switch ELECTRICIAN Ground To Fan (see above) Do Not Break Tab Break Tab Optional Accent Light on Neutral (silver terminals) Copper terminals Black Green Receptacle in Unit Regency Bellavista™ B41XT Gas Fireplace...
  • Page 46: Wiring Diagram For Ng And Lp Units

    Burner ON White White (To TH) Black To Thermocouple IN "S.I.T" Valve (To TH) T-Stat ON OFF Remote Receiver Remote Transmitter or Thermostat (Optional) (Millivolt) (Optional) WIRING DIAGRAM FOR GTMF REMOTE 2 ft. wiring harness Regency Bellavista™ B41XT Gas Fireplace...
  • Page 47 Note 1 ~ Profl ame Flame Modulator for GTM & GTMF Remote Controls are sold seperately. Choice of NG or LP fl ame modulator (to match unit fuel type). See Regency Retail Price pages for complete details Note: Regency Profl ame systems include a white and black wall cover & switch.
  • Page 48: Optional Accent Light Installation

    fi rebox base. Left side shown, repeat for right side. Diagram 2: Slide burner assembly to the right and then remove. 8) Remove the 2 screws securing the rear log tray and lift out. Diagram 3 Diagram 3 Regency Bellavista™ B41XT Gas Fireplace...
  • Page 49 14) Install a bulb into each light assembly. Note: Glass is longer than diffuser for ease of removal. Note: Oils from hands will shorten the life of the bulbs, do not handle bulbs with bare hands. 19) Reverse steps 9 - 1. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 50: Flush Glass Door Installation

    Slide the Finishing Trim Top over the Side Trim pieces and fi t the bottom bracket slots over the screws. Tighten the 2 screws to secure in place. B41XT B36XT 43-3/8" 40-1/2" Edge of Unit Finishing Trim 37-5/8" 35-3/4" Regency Bellavista™ B41XT Gas Fireplace...
  • Page 51: Louvers / Flush Panel Installation

    / fl ush panel with the corresponding bracket clip on the inside top of the unit (see below). 3. Flip the hinges down to 90° - line up the louver / fl ush panel as shown below. Location of bracket clips in unit. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 52: Full Screen Arch Door And Frame Installation

    fi nished fl ooring. The door frame can also be adjusted out 3/4" from the unit to accommodate fi nishing materials. See Diagram 4. 0" +3/4" Factory Diagram 2 Setting +3/4" Diagram 2a Diagram 4 Regency Bellavista™ B41XT Gas Fireplace...
  • Page 53 9) To install the lower screen mesh panel - line up the 2 hinges with the brackets in the unit as shown below. 13) Flip up the lower screen mesh panel to close. 10) Attach each hinge to the corresponding bracket with 2 screws as shown below. Regency Bellavista™ B41XT Gas Fireplace...
  • Page 54 Install the bracket to the fl ange at the base of the unit using 2 screws. There are 2 hole locations on the bracket to accom- modate fl ush wall & thicker fi nishing materials. Flush Wall Thicker Finishing Final Screen Door Install Screw Location Screw Location Regency Bellavista™ B41XT Gas Fireplace...
  • Page 55: Operating Instructions

    Use a non-abrasive 3) Turn the gas control knob to the "OFF" position cleaner and DO NOT ATTEMPT TO CLEAN to turn off the pilot. THE GLASS WHILE IT IS HOT. Regency Bellavista™ B41XT Gas Fireplace Regency Bellavista™ B41XT Gas Fireplace...
  • Page 56: Copy Of Lighting Plate Instructions

    3) Turn off all electric power to the appliance if service is to be performed. You may shut off the pilot during prolonged non use periods to conserve fuel. DO NOT REMOVE THIS INSTRUCTION PLATE 918-583 Regency Bellavista™ B41XT Gas Fireplace...
  • Page 57: Maintenance

    In the event that you break your glass by impact, THERMOPILE / purchase your replacement from an authorized 5) The appliance and venting system must be Regency dealer only. Replacement glass (Part THERMOCOUPLE inspected before use, and at least annually, #940-362/P) is shipped already installed into the by a qualifi...
  • Page 58: Accent Light Bulb Replacement

    Diagram 2: Slide burner assembly to the right and then remove. 11) Reverse steps 9 - 1. 8) Remove the 2 screws securing the rear log tray and lift out. Diagram 3 Diagram 3 Regency Bellavista™ B41XT Gas Fireplace...
  • Page 59: Valve Replacement

    fl ame appearance and glow on logs. Diagram 6 11) Remove the 14 screws securing the Diagram 3 valve tray assembly in place (Diagram 7) and then lift the entire assembly out (Diagram 8). Also remove the valve gasket. Diagram 7 Regency Bellavista™ B41XT Gas Fireplace...
  • Page 60: Main Assembly

    Oval Duct Adaptor 946-007 Angle Bracket Outerbox Assembly 946-517/P Fan Assembly - Heat Wave Firebox Assembly 946-004 Junction Box 506-959 Optional Accent Light 918-810 Manual * Not available as a replacement part. Regency Bellavista™ B41XT Gas Fireplace Regency Bellavista™ B41XT Gas Fireplace...
  • Page 61: Burner Assembly

    15) 506-062 Base Tray 506-055 Valve Tray Plate 10) 506-075 Air Defl ector 506-930 Log Set 11) 380-013 Pilot Holder Extruded 12) 910-038 Pilot Assembly - NG 910-039 Pilot Assembly - LP 910-386 Thermocouple 910-341 Thermopile Regency Bellavista™ B41XT Gas Fireplace...
  • Page 62: Accessories

    Brick Panels - Standard Cinder Gray 506-907 Inner Panels - Brushed Stainless Steel 506-908 Inner Panels - Black Enamel 507-940 Full Screen Doors - Black 507-942 Full Screen Doors - Midnight Grey 507-944 Full Screen Doors - Midnight Brown Regency Bellavista™ B41XT Gas Fireplace...
  • Page 63: Warranty

    Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly ® before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 64 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Bellavista is a trademark of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2011, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Bellavista b41xt-lp1

Table of Contents