2.2.4

Rotating the connectors

Power connectors, signal connectors, and DRIVE-CLiQ can be rotated to a limited extent.
Notice
The permissible range of rotation may not be exceeded.
In order to guarantee the degree of protection, a max. 10 revolutions are permissible.
Do not exceed max. torque when rotating connectors.
Connectors should be rotated using the mating connector that matches the connector
thread.
Connecting cables should be secured against strain and bending.
Motor connectors should be secured so that they cannot be rotated any further.
Connectors may not be subject to continuous force.
Direction and torque when rotating
Table 2-7
Direction and torque when rotating connectors
Connector
Power connector, size 0.5
Power connector, size 1
Power connector, size 1.5
Signal connector
DRIVE-CLiQ
Figure 2-8
Rotating a connector using an 1FK706 motor as an example
Synchronous Motors 1FK7
Configuration Manual, (PFK7S), Edition 12.2006, 6SN1197-0AD16-0BP1
Direction of rotation
Clockwise
270°
270°
270°
90°
180° for SH 20 to 80
90°
2.2 Electrical connections
Max. torque when
rotating
Counter-clockwise
not supported
not supported
not supported
90° for SH 100
180°
Application
8 Nm
8 Nm
15 Nm
8 Nm
8 Nm