Motor components
6.2 Encoder (option)
Connection assignment for 12/17-pin flange socket with pin contacts
Table 6-11
PIN No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Cables
Table 6-12
Connector size 0.5
Connector size 1
For other technical data and length code, refer to catalog, Chapter "MOTION-CONNECT
connection system"
78
Connection assignment for flange socket, 12-pin
Description of the signals
12-pin
Connector size 1 for
1FK702⃞ to 1FK710⃞
S2
S4
not connected
not connected
not connected
not connected
R2
+1R1
–1R2
R1
S1
S3
---
---
---
---
---
Prefabricated cable
6FX
6FX
17-pin
Connector size 0.5 for
1FK701⃞
+1R1
–1R2
not connected
S1
S3
not connected
S2
S4
not connected
R1
R2
not connected
not connected
not connected
not connected
not connected
not connected
5
002
-
2CF20
002
-
2CF02
5 MOTION-CONNECT
500
8 MOTION-CONNECT
800
Configuration Manual, (PFK7S), Edition 12.2006, 6SN1197-0AD16-0BP1
When viewing the plug-in side
(pins)
Connector size 1
Connector size 0.5
-
1⃞⃞
0
-
⃞⃞⃞
0
↓↓↓
Length
Max. cable length 130 m
Max. cable length 50 m