FABIA 2000
Electrical System
90-6
Self-diagnosis of the vehicle voltage control unit II
Fault table for the vehicle voltage control unit
Note
♦
All the possible faults which can be detected by the vehicle voltage control unit and can be displayed by
-V.A.G 1552- are listed below according to the 5-digit fault code.
♦
Before replacing components found to be defective first check the wiring and plug connections to these compo-
nents as well as the earth cables according to the current flow diagram.
♦
After repair always interrogate the fault memory using vehicle system tester -V.A.G 1552- and erase the memory.
♦
All static and sporadic faults are stored in the fault memory. A fault is detected as static if it exists for at least 2
seconds. If the fault is then no longer present, it is stored as a sporadic (temporary) fault. „/SP" appears on the right
of the display.
♦
After switching on the ignition, all the faults which exist are set to sporadic and are not stored as static faults unless
they continue to exist after completing the check.
♦
If a sporadic fault no longer occurs during 50 driving cycles (ignition on for at least 5 minutes, road speed > 30 km/
h), it is erased.
Readout on - V.A.G 1552-
00883
Ignition/starter
Implausible sig-
switch -D (terminal
nal
S)
00884
Ignition/starter
Implausible sig-
switch -D (terminal
nal
X)
00885
Ignition/starter
Implausible sig-
switch -D (terminal
nal
50)
00886
Turn signal switch -
Implausible sig-
E2
nal
00887
Hazard warning
Implausible sig-
light push-button -
nal
E229
00888
Intermittent wiper
Implausible sig-
switch -E22
nal
Edition 05.04
S00.5304.11.20
Possible causes of
fault
♦
Loose contact
♦
Corrosion at plug
connections
♦
Switch defective
♦
Loose contact
♦
Corrosion at plug
connections
♦
Push-button defec-
tive
♦
Loose contact
♦
Corrosion at plug
connections
♦
Switch defective
Self-diagnosis of the vehicle voltage control unit II
Possible ef-
Rectifying fault
fects
Test wiring ⇒ Current Flow
–
Diagrams, Electrical Fault
Operating
Finding and Fitting Locations.
problems
–
Check connectors.
–
Replace switch.
Test wiring ⇒ Current Flow
–
Diagrams, Electrical Fault
Operating
Finding and Fitting Locations.
problems
–
Check connectors.
–
Replace push-button.
Test wiring ⇒ Current Flow
–
Diagrams, Electrical Fault
Operating
Finding and Fitting Locations.
problems
–
Check connectors.
–
Replace switch.
90