Self-Diagnosis Of The Vehicle Voltage Control Unit Ii; Fault Table For The Vehicle Voltage Control Unit - Skoda FABIA 2000 Workshop Manual

Hide thumbs Also See for FABIA 2000:
Table of Contents

Advertisement

FABIA 2000
Electrical System
90-6

Self-diagnosis of the vehicle voltage control unit II

Fault table for the vehicle voltage control unit

Note
All the possible faults which can be detected by the vehicle voltage control unit and can be displayed by
-V.A.G 1552- are listed below according to the 5-digit fault code.
Before replacing components found to be defective first check the wiring and plug connections to these compo-
nents as well as the earth cables according to the current flow diagram.
After repair always interrogate the fault memory using vehicle system tester -V.A.G 1552- and erase the memory.
All static and sporadic faults are stored in the fault memory. A fault is detected as static if it exists for at least 2
seconds. If the fault is then no longer present, it is stored as a sporadic (temporary) fault. „/SP" appears on the right
of the display.
After switching on the ignition, all the faults which exist are set to sporadic and are not stored as static faults unless
they continue to exist after completing the check.
If a sporadic fault no longer occurs during 50 driving cycles (ignition on for at least 5 minutes, road speed > 30 km/
h), it is erased.
Readout on - V.A.G 1552-
00883
Ignition/starter
Implausible sig-
switch -D (terminal
nal
S)
00884
Ignition/starter
Implausible sig-
switch -D (terminal
nal
X)
00885
Ignition/starter
Implausible sig-
switch -D (terminal
nal
50)
00886
Turn signal switch -
Implausible sig-
E2
nal
00887
Hazard warning
Implausible sig-
light push-button -
nal
E229
00888
Intermittent wiper
Implausible sig-
switch -E22
nal
Edition 05.04
S00.5304.11.20
Possible causes of
fault
Loose contact
Corrosion at plug
connections
Switch defective
Loose contact
Corrosion at plug
connections
Push-button defec-
tive
Loose contact
Corrosion at plug
connections
Switch defective
Self-diagnosis of the vehicle voltage control unit II
Possible ef-
Rectifying fault
fects
Test wiring ⇒ Current Flow
Diagrams, Electrical Fault
Operating
Finding and Fitting Locations.
problems
Check connectors.
Replace switch.
Test wiring ⇒ Current Flow
Diagrams, Electrical Fault
Operating
Finding and Fitting Locations.
problems
Check connectors.
Replace push-button.
Test wiring ⇒ Current Flow
Diagrams, Electrical Fault
Operating
Finding and Fitting Locations.
problems
Check connectors.
Replace switch.
90
90-6
1
page

Hide quick links:

Advertisement

Table of Contents
loading