FABIA 2000
Electrical System
90-3
Self-diagnosis of the dash panel insert II
Fault table for the dash panel insert
Note
♦
All the possible faults which can be detected by the vehicle system tester -V.A.G 1552- are listed below according
to the 5-digit fault code.
♦
Before replacing components found to be defective first check the wiring and plug connections to these compo-
nents as well as the earth cables according to the current flow diagram.
♦
After repair once again interrogate the fault memory using vehicle system tester -V.A.G 1552- and then erase the
memory.
♦
All static and sporadic faults are stored in the fault memory. A fault is detected as static if it exists for at least 2
seconds. If the fault is then no longer present, it is stored as a sporadic (temporary) fault. „/SP" appears on the right
of the display.
♦
After switching on the ignition, all the faults which exist are set to sporadic and are not stored as static faults unless
they continue to exist after completing the check.
♦
If a sporadic fault no longer occurs during 50 driving cycles (ignition on for at least 5 minutes, road speed > 30 km/
h), it is erased.
Display -V.A.G 1552-
00562
Short circuit after
the positive
Sender for oil lev-
Short circuit after
el/temperature -
the earth
E266
an implausible
signal
00771
Open circuit in
wiring or short cir-
Fuel gauge send-
cuit to positive
er -G
Short circuit to
earth
00779
Open circuit in
wiring or short cir-
Outside temp.
cuit to positive
sensor -G17
Short circuit to
earth
Edition 10.03
S00.5304.10.20
Possible cause of
fault
♦
Open circuit in wir-
ing or short circuit
to positive or to
earth in the cable
connection be-
tween - E266 and
the dash panel in-
sert
♦
Sender - E266 de-
fect
♦
Open circuit in wir-
ing or short circuit
to positive or to
earth in the cable
connection be-
tween fuel gauge
sender -G- and
dash panel insert
♦
Fuel gauge send-
er - G- defective
♦
Open circuit in wir-
ing or short circuit
to positive or to
earth in the cable
connection be-
tween outside
temp. sensor
-G17- and dash
panel insert
♦
Outside temp.
sensor -G17-
faulty
Self-diagnosis of the dash panel insert II
Possible effects
upon switching on the ig-
nition the yellow warning
light for the oil level blinks
Fuel gauge is on empty
Only „- - -" appear in the
display of the multifunc-
tion display
90
Rectifying fault
–
Test wiring
⇒ Current Flow Di-
agrams, Electrical
Fault Finding and
Fitting Locations.
–
Check connectors.
–
Replace sender -
E266.
–
Test wiring
⇒ Current Flow Di-
agrams, Electrical
Fault Finding and
Fitting Locations.
–
Check connectors.
–
Reading meas-
ured value block
002 ⇒ Chap. 90-4
–
Test fuel gauge
⇒ Chapter 90-4
–
Test wiring
⇒ Current Flow Di-
agrams, Electrical
Fault Finding and
Fitting Locations.
–
Check connectors.
–
Reading meas-
ured value block
002 ⇒ Chap. 90-4.
–
Replace outside
temp. sensor
-G17-.
90-3
1
page