Self-Diagnosis Of The Dash Panel Insert Ii; Fault Table For The Dash Panel Insert - Skoda FABIA 2000 Workshop Manual

Hide thumbs Also See for FABIA 2000:
Table of Contents

Advertisement

FABIA 2000
Electrical System
90-3

Self-diagnosis of the dash panel insert II

Fault table for the dash panel insert

Note
All the possible faults which can be detected by the vehicle system tester -V.A.G 1552- are listed below according
to the 5-digit fault code.
Before replacing components found to be defective first check the wiring and plug connections to these compo-
nents as well as the earth cables according to the current flow diagram.
After repair once again interrogate the fault memory using vehicle system tester -V.A.G 1552- and then erase the
memory.
All static and sporadic faults are stored in the fault memory. A fault is detected as static if it exists for at least 2
seconds. If the fault is then no longer present, it is stored as a sporadic (temporary) fault. „/SP" appears on the right
of the display.
After switching on the ignition, all the faults which exist are set to sporadic and are not stored as static faults unless
they continue to exist after completing the check.
If a sporadic fault no longer occurs during 50 driving cycles (ignition on for at least 5 minutes, road speed > 30 km/
h), it is erased.
Display -V.A.G 1552-
00562
Short circuit after
the positive
Sender for oil lev-
Short circuit after
el/temperature -
the earth
E266
an implausible
signal
00771
Open circuit in
wiring or short cir-
Fuel gauge send-
cuit to positive
er -G
Short circuit to
earth
00779
Open circuit in
wiring or short cir-
Outside temp.
cuit to positive
sensor -G17
Short circuit to
earth
Edition 10.03
S00.5304.10.20
Possible cause of
fault
Open circuit in wir-
ing or short circuit
to positive or to
earth in the cable
connection be-
tween - E266 and
the dash panel in-
sert
Sender - E266 de-
fect
Open circuit in wir-
ing or short circuit
to positive or to
earth in the cable
connection be-
tween fuel gauge
sender -G- and
dash panel insert
Fuel gauge send-
er - G- defective
Open circuit in wir-
ing or short circuit
to positive or to
earth in the cable
connection be-
tween outside
temp. sensor
-G17- and dash
panel insert
Outside temp.
sensor -G17-
faulty
Self-diagnosis of the dash panel insert II
Possible effects
upon switching on the ig-
nition the yellow warning
light for the oil level blinks
Fuel gauge is on empty
Only „- - -" appear in the
display of the multifunc-
tion display
90
Rectifying fault
Test wiring
⇒ Current Flow Di-
agrams, Electrical
Fault Finding and
Fitting Locations.
Check connectors.
Replace sender -
E266.
Test wiring
⇒ Current Flow Di-
agrams, Electrical
Fault Finding and
Fitting Locations.
Check connectors.
Reading meas-
ured value block
002 ⇒ Chap. 90-4
Test fuel gauge
⇒ Chapter 90-4
Test wiring
⇒ Current Flow Di-
agrams, Electrical
Fault Finding and
Fitting Locations.
Check connectors.
Reading meas-
ured value block
002 ⇒ Chap. 90-4.
Replace outside
temp. sensor
-G17-.
90-3
1
page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents