Optional air filters

Optional air filters
You can purchase an optional NEBS compliant air filter kit that includes a front filter that fits over the front of the
chassis and two filters for the side cool air intakes. These filters are not required for normal operation but can be
added if you require air filtration.
The air filters should be inspected regularly. If dirty or damaged, the filters should be disposed of and replaced.
The air filters can be fragile and should be handled carefully.

AC Power Supply Units (PSUs) and supplying AC power to the chassis

The AC version of the FortiGate-7060E chassis front panel includes four hot swappable DC PSUs. At least three
PSUs (1, 2, and 3) must be connected to power. Power supplies 4 to 6 are backup power supplies that provide
3+1 , 3+2, and 3+3 redundancy. See
All PSUs should be connected to AC power. To improve redundancy you can connect each power supply to a
separate power source.
Use a C15 Power cable, supplied with the chassis, to connect power to each PSU C16 power connector. C15/C16
power connectors are used for high temperature environments and are rated up to 120°C.
AC PSU showing C16 power connector
C16
Power
Connector
The PSU LED indicates whether the PSU is operating correctly and connected to power. If this LED is not lit check
to make sure the PSU is connected to power. If the power connection is good then the PSU has failed and should
be replaced.

Hot Swapping an AC PSU

Follow these steps to safely hot swap an AC PSU.
13
FortiGate-7060E front panel on page 5
Latch
PSU
LED
You can hot swap a PSU without powering down the FortiGate-7060E as long as three
PSUs are connected to power and operating normally. If you need to hot swap one of
three operating PSUs you must power down the chassis first.