Fortigate-7060E Chassis Schematic - Fortinet FortiGate-7060E System Manual

8u 19-inch rackmount 6-slot chassis with a 80gbps fabric and 1gbps base backplane
Hide thumbs Also See for FortiGate-7060E:
Table of Contents

Advertisement

FortiGate-7060E Chassis
register, enter your contact information and the serial numbers of the Fortinet products that you or your
organization have purchased.

FortiGate-7060E chassis schematic

The FortiGate-7060E chassis schematic below shows the communication channels between chassis components
including the management modules (MGMT), the FIM modules (called FIM1 and FIM2) and the FPM modules
(FPM3, FPM4, FPM5, and FPM6).
80G
80G
80G
80G
80G
80G
80G
80G
40G
40G
80G
80G
80G
80G
80G
80G
80G
80G
By default MGMT2 is the active management module and MGMT1 is inactive. The active management module
always has the IPMB address 0x20 and the inactive management module always has the IPMB address 0x22.
The active management module communicates with all modules in the chassis over the base backplane. Each
module, including the management modules has a Shelf Management Controller (SMC). These SMCs support
Intelligent Platform Management Bus (IPMB) communication between the active management module and the
FIM and FPM modules for storing and sharing sensor data that the management module uses to control chassis
cooling and power distribution. The base backplane also supports serial communications to allow console access
from the management module to all modules, and 1Gbps Ethernet communication for management and
heartbeat communication between modules.
FIM1 and FIM2 (IPMB addresses 0x82 and 0x84) are the FIM modules in slots 1 and 2. The interfaces of these
modules connect the chassis to data networks and can be used for Ethernet management access to chassis
components. The FIM modules include DP2 processors that distribute sessions over the Integrated Switch Fabric
(ISF) to the NP6 processors in the FPM modules. Data sessions are communicated to the FPM modules over the
80Gbps chassis fabric backplane.
FortiGate-7060E System Guide
Fortinet Technologies Inc.
MGMT1 (inactive by default, IPMB 0x22)
FPM Module
NP6 CP9
FPM Module
NP6 CP9
FIM Module
DP2
ISF
FIM Module
DP2
ISF
FPM Module
NP6 CP9
FPM Module
NP6 CP9
MGMT2 (active by default, IPMB 0x20)
SMC SDI
MGMT
Data
M1 M2
1-4
Interfaces
MGMT
Data
M1 M2
1-4
Interfaces
FortiGate-7060E chassis schematic
IPMB
SMC SDI
SERIAL
1G
FPM5 IPMB 0x8A
IPMB
SERIAL
SMC SDI
1G
FPM3 IPMB 0x86
IPMB
SERIAL
SMC SDI
1G
FIM1 IPMB 0x82
PMB 0x82
IPMB
SMC SDI
SERIAL
1G
FIM2 IPMB 0x84
PMB 0x84
IPMB
SERIAL
SMC SDI
1G
FPM4 IPMB 0x88
PMB 0x88
IPMB
SERIAL
SMC SDI
1G
FPM6 IPMB 0x8C
PMB 0x8C
IPMB
SERIAL
SMC SDI
1G
8