Service Indicator Diagnostics - Invacare Pronto M41 Service Manual

With surestep
Hide thumbs Also See for Pronto M41:
Table of Contents

Advertisement

SECTION 3—SAFETY INSPECTION/TROUBLESHOOTING

Service Indicator Diagnostics

1
E 01
User Fault
2
E02
Battery Fault
3
E03
Left Motor Fault
4
E04
Right Motor Fault
®
Pronto
M41
00
Stall Timeout or user error.
00
Recharge batteries or replace. Check the batteries and cable. Try charg-
00
Left Motor Short Circuit
01
Left Motor Open Circuit
02
Left Motor Connection Fault
B-
03
Motor Terminal Connected
to B+
04
Left Motor Voltage Fault
05
Left Motor Bridge Fault
06
Too Many Hardware Current
Limit Events
07
Current Offset Out of Range
08
Hardware Current Limit Fault
00
Right Motor Short Circuit
01
Right Motor Open Circuit
02
Right Motor Connection Fault
B-
03
Motor Terminal Connected
to B+
04
Right Motor Voltage Fault
05
Right Motor Bridge Fault
06
Too Many Hardware Cur-
rent Limit Events
07
Current Offset Out of Range
08
Hardware Current Limit Fault
20
Release joystick to neutral and try again.
ing the batteries. Batteries may require
replacing.
Check the left motor, connections and
motor cable.
Check the right motor, connections and
motor cable.
Part No 1145724